Home " Exhaust air control cable

Shows all 6 results

Cable exhaust control KDS 110 DIBt

Item no.: 300740
99,00 
The magnetic switch of the KDS 110 set with DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with a potential-free 5 A change-over relay. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Depending on the connection option (e.g. Miele PUR 98), the light of the bonnet can also be switched on independently of the window position.

Cable magnetic switch KMS 098K22

Item no.: 300743
19,90 
Additional magnetic switch for KDS 110/116/210 and KDT 210 The additional magnetic switch for a second (or more) window is equipped with 2 screw terminals and is mounted between the control unit and the original magnetic switch. The connection is made with a 2-wire LiYY control cable. The OR function is achieved, only one of the two windows must be open for an exhaust air control KDS / KDT to release the fan motor or an air conditioning control KKS to switch off the air conditioning.

Cable exhaust control with thermal switch KDT 210

Item no.: 300674
249,00 
This package without DIBt approval includes a classic cable exhaust air control set KDS 210 consisting of a window solenoid switch with intermediate plug control unit and an exhaust gas temperature monitor ATW 519 with integrated cable breakage protection for a free piece of stove pipe that is accessible at any time, with all components already pre-assembled. Due to the additional temperature switch, the exhaust air system can be operated independently of the window position as long as the furnace is cold; opening the window is only necessary when the furnace is in operation. Hint: Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences over which Elektrotechnik Schabus has no influence.  

Possible applications

  • Fume cupboard control
  • Exhaust air control

Cable exhaust control KGS 116

Item no.: 300715
79,00 
The KGS 116 cable gas heater control unit interrogates the potential-free normally open contact of a gas heater and converts the change of state of the gas heater into a changeover of the potential-free changeover relay. With this system, e.g. a bathroom fan can be switched off when the gas heater is ignited. Possible applications
  • Gas boiler in combination with bathroom fan

Cable exhaust control KDS 210 DIBt

Item no.: 300672
119,90 
The magnetic switch of the KDS 210 set with DIBt approval monitors the window position and transmits the information via a thin cable to an intermediate plug control unit with a switched 5 A socket. In this way, an exhaust air system can only be operated with a tilted or open window if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Possible applications
  • Fume cupboard control
  • Exhaust air control
  • for trough fans is only KDS 110 suitable

Cable exhaust control KDS 116

Item no.: 300750
79,00 
Cable exhaust control with built-in unit! The magnetic switch of the KDS 116 without DIBt approval monitors the window position and transmits the information via a thin cable to a built-in control unit with potential-free 16 A changeover relay. For example, an exhaust air laundry dryer can only be operated with the window tilted or open if it is ensured that sufficient fresh air flows into the room and thus no negative pressure is created that could draw dangerous and toxic carbon monoxide from a combustion site. Possible applications
  • Fume cupboard control
  • Bathroom fan control
  • Exhaust air clothes dryer