Home › Alle Produkte › Cable exhaust air control KGS 116

Cable exhaust air control KGS 116

Überwacht die Fensterstellung und verhindert gefährlichen Unterdruck bei gleichzeitigem Betrieb von Abluftanlage und Gastherme
  • Exhaust air system, e.g. bathroom fan, can be operated safely despite gas boiler
  • As soon as the gas boiler is ignited, the control system reliably switches off the exhaust air system
  • Gas boiler in combination with bathroom fan
  • Cable break protection
  • Terminal connections control unit
  • Relay contact 16 A changeover contact (potential-free)
🧹 Vom Schornsteinfeger gefordert? Wer eine Abluftanlage zusammen mit einer raumluftabhängigen Feuerstätte betreibt, braucht eine geprüfte Sicherheitseinrichtung nach Feuerungsverordnung, damit kein gefährlicher Unterdruck entsteht – dieses Gerät erfüllt genau diese Aufgabe.
79,00 €inkl. MwSt. zzgl. Versand
Auf Lager · Lieferzeit 4–5 Werktage mit DHL
Art.-Nr.: 300715EAN: 4044764001114
PayPal Klarna Mastercard Visa Google Pay Apple Pay Shop Pay
Versandkostenfreiab 100 €
5 JahreGarantie ›
14 TageWiderrufsrecht

Scope of delivery

  • control unit
  • 4 m control cable
  • Mounting material
  • Operating instructions

Exhaust systems such as bathroom fans or extractor hoods create negative pressure in the room if there is insufficient fresh air flow. If a fireplace (e.g., gas boiler, central heating boiler) is located in the same room, there is a risk that toxic exhaust gases – such as carbon monoxide – will be sucked back into the living space from the chimney.

The KGS 116 exhaust air control system prevents precisely this risk: It only allows the exhaust air system to operate when the fireplace is not in use.

The control unit is permanently connected to the potential-free contact of the gas boiler (normally open). As soon as the boiler ignites, the KGS 116 detects the changed contact state and interrupts the power supply to the connected exhaust air system.

If the gas boiler is deactivated again, the control system automatically releases the exhaust air system again.

Safety principle: Exhaust air is only permitted if no exhaust gases can be produced.

Connection example

The KGS 116 cable gas boiler control system queries the potential-free normally open contact of a gas boiler and converts the gas boiler's state change into a switching of the potential-free changeover relay. This system can be used to turn off a bathroom fan, for example, when the gas boiler is ignited.

The KGS 116 control unit is connected to the potential-free contact (normally open) of the gas boiler with a cable. As soon as combustion starts, the exhaust air system (e.g., bathroom fan) is switched off. The control unit can be installed surface-mounted or flush-mounted in a distribution box, switch, or socket with a minimum diameter of 60 mm. The side mounting tabs on the control unit can be removed if necessary.

WEEE NO.: DE91394868

  • Steuergerät
  • 4 m Steuerleitung
  • Montagematerial
  • Betriebsanleitung
Betriebsspannung230 V AC / 50 Hz
Schaltleistung3500 VA (2300 W), 16 A (10 A)
SchutzartIP20
Betriebstemperatur-15°C / +40°C
Abmessungen (H×B×T)

51x51x26 mm

Anschlussleitung4 meters, special length on request
  • ✓ Versand mit DHL – Lieferzeit 4–5 Werktage
  • ✓ 14 Tage Rückgaberecht
  • ✓ Reparatur & Ersatzteile direkt vom Hersteller
  • ✓ Kauf auf Rechnung möglich

Warum direkt beim Hersteller kaufen?

Zugelassen & anerkannt

Keine No-Name-Ware: Unsere Geräte sind geprüft, zugelassen und werden vom Fachhandwerk anerkannt.

Sofort einsatzbereit

Empfänger, Sender, Magnet, Batterie & Montagematerial – alles dabei, nichts nachzukaufen.

Reparatur & Ersatzteile

Reparatur und Ersatzteile direkt vom Hersteller – auch über die gesetzliche Gewährleistung hinaus.

Häufige Fragen

Gut zu wissen

🛠️ Technology & function

How exactly does the KGS 116 exhaust air control work? The KGS 116 is connected directly to a potential-free contact on the gas boiler via cable. As soon as the heater goes into operation and switches the contact, the control recognizes the signal and automatically interrupts the power supply to the exhaust system. After the heater is switched off, the exhaust system is released again.

Which devices can I control with the KGS 116? The control is suitable for all exhaust air systems with 230V alternating voltage up to max. 1,150W, e.g. E.g. bathroom fans, extractor hoods or pipe fans.

What if the gas boiler fails or the line is interrupted? The KGS 116 works according to the safety principle “exhaust air is only permitted when the heater is switched off”. If the control signal disappears, the exhaust system remains switched off - a safe condition is guaranteed.

🧰 installation

Where is the KGS 116 installed? The KGS 116 is a built-in device in a slightly hexagonal format for typical flush-mounted or cavity wall boxes. It is usually installed near the exhaust system, ideally where the mains connection is located.

What do I do if my gas boiler outputs 230V when starting instead of a potential-free signal? In this case, an electrician can install a standard 230V relay. When activated, this creates a potential-free contact that the KGS 116 recognizes and evaluates. A simple and secure solution.

Can I install the KGS 116 myself? We recommend installation by a trained electrician. The control intervenes in the mains power and requires a secure connection in accordance with VDE regulations.

⚖️ Legal

Is exhaust air control required by law? In many cases yes. The federal states' combustion regulations (FeuVO) stipulate that exhaust systems and fireplaces may only be operated together if safe operation is ensured - e.g. B. through a technical safety device such as the KGS 116.

Is the KGS 116 approved? No, we do not have DIBt certification for this article. Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are clear regional differences on which Elektrotechnik-Schabus has no influence.

🛒 purchase & service

Is the KGS 116 also suitable for other heating systems? Yes, provided there is a potential-free contact, the KGS 116 can also be used with oil heaters or other gas-powered systems.

Are there accessories or extensions for the KGS 116? The KGS 116 is an independent device without a radio system. It cannot be expanded, but can be flexibly adjusted using an upstream relay or contactor.

How long does the guarantee last? You receive a 2-year warranty in accordance with legal regulations.

Who will support me if I have any questions or problems? Our technical support is available by phone or email. You can find the contact details on our website.

Häufig zusammen gekauft

Kunden kauften auch

Alle ansehen →
Familienunternehmen aus Oberbayern

Sicherheit „Made in Germany“ – seit 1992

Wir entwickeln und fertigen zuverlässige Mess- und Meldesysteme selbst – vom ersten Prototyp bis zum Reparaturservice, alles aus einer Hand. Unsere Produkte schützen Leben und schaffen Vertrauen.

  • Zugelassen, nicht nur billig – DIBt-geprüft & anerkannt
  • Das komplette System aus einer Hand, sofort einsatzbereit
  • Service, Ersatzteile & Reparatur direkt aus Bayern
1992
gegründet
30+
Jahre Erfahrung
30.000
zufriedene Kunden
DIBt
zugelassen & TÜV
Wolfgang & Petra Schabus
Das Team von Elektrotechnik Schabus in Oberbayern
Was Kunden sagen

Darauf verlassen sich unsere Kunden

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Newsletter

10 % Rabatt auf Ihre erste Bestellung

Sicherheits-Tipps, Neuheiten & exklusive Angebote – jederzeit abbestellbar.

Geprüfte Bewertungen bei ProvenExpert

Unabhängig verifizierte Kundenstimmen zu Beratung, Service & Reparatur. (Das echte ProvenExpert-Siegel binden wir vor dem Live-Gang ein.)

Gesetzliche Gewährleistung – mindestens 2 Jahre in der EU

Gesetzliche Gewährleistung: Mindestens zwei Jahre gesetzliche Gewährleistung der Vertragsmäßigkeit für Waren, die in der Europäischen Union verkauft werden. Bei vertragswidriger Ware: kostenlose Nachbesserung oder Ersatzlieferung, in bestimmten Fällen Preisminderung oder vollständige Erstattung des Kaufpreises.

Zum Vergrößern auf das Label tippen.