The external CO2 sensor with its own alarm transmitter, status LEDs and test button is optimized as an accessory for the SCHABUS gas warning devices GX-HS and GX-A1+. Its warning levels and IP54 protection class are based on the Beverage Dispensing Systems Ordinance. For use in the catering industry, this NDIR sensor was designed for an alarm threshold of 1.5% vol. CO2 for pre-alarm, 3.0% vol. CO2 for main alarm.
The detected CO2 concentration is transmitted to the warning device via an analog voltage, which can then switch a potential-free changeover relay when the alarm threshold is reached.
The connecting cable of the sensor can be extended. The following minimum cross-sections apply depending on the length of the cable: Cable cross-section 3 x 0.75 mm²: maximum length 10 m Cable cross-section 3 x 1.5 mm²: maximum length 20 m A high-tech membrane is located behind the housing openings to keep water away from the electronics. Although the sensor is not waterproof, it is not immediately damaged when water splashes from normal cleaning activities hit the sensor.
PerformanceFeatures
- External NDIR sensor for the GX-A1+ gas detector
- LED indicators for operation, fault, alarm directly on the sensor
- Detection of carbon dioxide (CO2) in beverage dispensing systems, wine cellars and all gas systems with CO2 from bottles, also dry ice storage systems
- Pre-alarm triggering at 2.5 % volume concentration
- Main alarm Triggered at 3 % volume concentration
- Integrated buzzer for direct alarm signalling
Scope of delivery
- Gas sensor with molded cable
- 6 m cable, white, 3×0.14 mm²
- 2 mounting screws and dowels
- detailed operating instructions with assembly instructions
Technical data
Operating voltage: | 12-24 VDC / > 150 mA |
Humidity (ambient): | 5-90 % RH (non-condensing) |
Functional area: | 0 °C / +50 °C |
Storage temperature: | -20° C / +60° C |
Measuring range: | approx. 400 ppm to approx. 5% CO2 |
Measuring frequency: | approx. 15 measurements in 10 seconds |
Accuracy: | ± 100 ppm / ± 5% |
internal buzzer: | > 82 dB / 10 cm |
Lifespan: | approx. 5 years, depending on ambient conditions |
Protection class: | IP 54 sensor element |
Cable length: | 6 m |
Cable Ø: | 3×0.14 mm² |
External dimensions (HxWxD): | 88x58x38 mm |
WEEE NO.: EN91394868