Performance features
- smallest design, high temperature resistant due to special metals and ceramics
- approved for use in heat generating plants,TÜV DIN tested, DIN EN 14597_2012-09
- intrinsically safe design, maintenance-free with professional mounting on the flue pipe
- Changeover contact with radio transmitter 868 MHz for release of the exhaust air system in case of cold combustion site
- max. medium temperature 500°C, at guard plate 180°C, at switch / transmitter housing max. 65°C
- external short helix antenna for best radio performance
- internal lithium battery for up to 6 months operation
- Increased safety, release of the exhaust air system only with functioning window solenoid or thermoswitch
- the assembly is carried out by a specialist company
Hint: When mounting the probe, make sure that it is not bent or damaged.
FTW transmitter housing is black. Window transmitter is telegrey, on request at extra charge in any RAL color
Scope of delivery
- 1x FDS 200 built-in receiver with DIBt approval Z-85.2-10
- 1x FDS 200 window contact transmitter with DIBt approval Z-85.2-10
- 1x window contact magnet
- 4x spacer plates for magnet
- 1x radio temperature monitor (transmitter) without DIBt, tested according to DIN EN 14597
- 1x battery CR2 3V Longlife
- 1x battery CR2032 3V
- Mounting material
Technical data receiver FDS 200
Operating voltage: | 230 V~ / 50 Hz |
Power consumption: | approx. 5.5 W |
Relay switching capacity: | 1150 VA / 5 A |
Radio frequency: | 868 MHz |
Reach: | up to max. 20 m in free field |
Functional area: | -15° C / +40° C |
Protection class: | IP 40 |
Receiver (HxWxD): | 121x57x46 mm |
Technical data window contact switch FDS 200
Switching threshold: | up to max. 1.5 cm to the magnet |
Response time: | less than 0.5 seconds |
Assembly: | Fastening to window frame and sash |
Dimensions transmitter (LxWxH): | 55x31x18 mm |
Dimensions magnet (LxWxH): | 55x15x18 mm |
Frequency: | 868 MHz SRD |
Reach: | Up to 20 metres in the open field |
Battery included: | CR2032 3 Volt |
Technical data temperature control transmitter FTW 519
Switching threshold: | 40°C +/-7K, approx. 15K Hysteres |
max. sensor temperature: | 500°C |
max. ambient temperature: | 180°C |
max. switch housing temperature: | 65°C |
Response time: | less than 45 seconds |
Assembly: | 3 holes in the flue pipe, must be mounted by specialist company |
Dimensions (HxWxD): | approx. 183x68x85 mm, incl. antenna |
Battery included | CR2 3 Volt Longlife |
WEEE NO.: EN91394868
Always recommended from previous construction projects
Good instructions, simple assembly, safe function