DS 01 L Comfort package for pellet primary st ove Suitable for monitoring the simultaneous operation of controlled ventilation systems and wodtke pellet primary stoves. Scope of delivery
- 21000 DS-01 L Differential pressure controller
- 21013 Special connection cable
- 21003 Pressure measurement adapter
- 21004 Pressure measuring tube
- 21002 Silicone hose, 5 meters
- detailed operating and assembly instructions
Technical data
Operating voltage: | 230 V AC / 50 Hz |
Power consumption: | max. 3 VA |
Permissible pressure range: | -50 to +200 Pa |
Nominal measuring range: | -50 to + 50 Pa |
Overload capacity: | up to 1 kPa |
Switching relay: | max. 2 A / 250 V (AC) or 50 V (DC) |
Functional area: | 0° C / +60° C |
Protection class: | IP 54 |
Control unit (HxWxD): | 120 x 120 x 75 mm |
WEEE NO.: EN91394868