Starting current limiter & cable

Starting current limiter

Accessories

 

... more relaxed for sure

made in Germany

The starting current limiters are used in conjunction with AC electric motors and power tools. They are also suitable for capacitor motors, large transformers and halogen lamps.

This electronic current limiter prevents the house fuse from being triggered by high inrush currents.

Overview starting current limiter & cables

Starting current limiter

Starting current limiter ASB 116 2500W/10A

Item no.: 300116
149,00 
The ASB 116 starting current limiter limits the machine connection power of an AC electric motor or power tool starting in no-load operation for around 700 milliseconds immediately after switching on, thus preventing the fuses from blowing.

Starting current limiter ASB 120 3500W/16A

Item no.: 300118
189,00 
The ASB 120 starting current limiter limits the current of a machine starting in no-load operation the machine connection power for about 700 milliseconds immediately after it is switched on and then switches the current fully through in order to effectively prevent the house circuit breaker on the public power supply system from tripping during the time phase in which the magnetic field of the coils of an electric motor has not yet been established.

Cables & Accessories

Cable H07RN-F 3×2,5mm² Titanex

Item no.: 05.06406.0
8,50 
Highly flexible and extremely resilient rubber hose cable Flexibility has a name - TITANEX - H07 RN-F is the number 1 among rubber hose lines. TITANEX is used in areas where the application criteria are absolutely important and must be met exactly.

Cable H07RN-F Titanex 3×1,5mm²

Item no.: 05.06382.0
7,50 

Highly flexible and extremely resilient rubber hose line

SchuKo coupling 230 V

Item no.: 05.07384.0
18,50 
High-quality coupling for extreme loads!

SchuKo plug 230 V

Item no.: 05.06381.0
16,90 
High-quality plug for extreme loads!

Special connection cable 4-core 5 metres

Item no.: 21013
39,90 
5 meter 4-core special connection cable for wodtke pellet primary stoves, for wiring the components including a strain relief with locknut (M16 x 1.5

Control cable LIYY meter goods

Item no.: 300780
3,90 
Possible applications
  • Flexible cable LIYY (2 x 0.14 mm²)
  • Diameter 3.0 mm
  • Yard goods - determine the total length via the number of pieces

Extension cable Schuko 3×1,5mm 10m

Item no.: 300110
65,50 
This 10 meter long, flexible and highly durable extension cable is carefully handmade from the very best components such as the TITANEX cable 3x 1.5mm², ABL Sursum plug and coupling and each individually tested according to VDE by an expert in his field for highest insulation and lowest protective conductor resistance. This makes it extremely resilient, meets the highest demands and is virtually predestined for rough use in industrial operations, on construction sites or in event technology, i.e. in areas in which the application criteria are absolutely important and must be met exactly. Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

Extension cable Schuko 3×1,5mm 20m

Item no.: 300120
109,90 
Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

Extension cable Schuko 3×1,5mm 30m

Item no.: 300130
175,50 
Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

Extension cable Schuko 3×1,5mm 40m

Item no.: 300140
229,90 
Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

Extension cable Schuko 3×1,5mm 50m

Item no.: 300150
259,90 
Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

Extension cable Schuko 3×2,5mm 10m

Item no.: 300210
75,90 
Possible applications
  • Industrial enterprises
  • public buildings
  • Event technology
  • Site equipment
  • and much more.

FAQ - Frequently asked questions

How exactly does this work with the ASB?

Electric motors make an axis rotate with magnetic fields. The magnetic field is generated with copper coils when current flows through the wire. Before the magnetic field has been established after switching on, the copper wire "looks" like a short circuit to the fuse. It almost is one, after all, there is a conductive connection between the two terminals and the fuse "flies out" because enormous currents flow in that brief moment, see the tripping diagram. The ASB connects a power resistor in front of the copper coil, which "consumes" the excess current as heat in a flash and thus limits the current. After 0.7 seconds, the magnetic field has long since built up, the motor turns and consumes the current itself, and only then does a relay in parallel with the power resistor switch the power supply fully on. The ASB itself has only the function of a normal line when the machine is running and the power resistor can cool down again.

My compressor only has 2000 watts. Why doesn't it even work with the ASB 120?

Electric motors that start at idle draw a very high current for a very short time when they are switched on. If this is limited by the ASB, the motor starts anyway. If the motor starts under load because it has to move the pistons of the compressor against the pressure in the boiler, it cannot start with the limited current. If the ASB now switches on fully after 0.7 seconds, the full starting current is still drawn. The limitation had no effect and the fuse "blows". The ASB does not help here.

My inverter produces 2300 watts, the Flex only needs 1000 watts. Why shouldn't that work with the ASB?

An inverter turns a DC voltage, e.g. a 12-volt car battery, into an AC voltage of 230 volts and can supply about 10 amps at the rated power. An electronic system regulates current and voltage, the regulation takes a certain amount of time and this is not available for the rapid load change. At the moment of switching on, the ASB limits the high starting current, but it switches on fully after 0.7 seconds and a lot of current is still needed quickly. Since no inverter has large capacitors that could supply large currents very quickly and the connected car battery is too sluggish, the voltage at the inverter collapses. Either the fuse on the inverter "blows" or the internal protective circuits simply switch off the inverter.

Does an ASB 120 work with an inverter generator?

Yes - if the inverter is a pure sine wave inverter.

No, if the inverter has a square wave output.

Shopping cart
Store
1 item Shopping cart
My account
Menu
Cookie Consent with Real Cookie Banner