Functional description
By using the KDS 110 cable exhaust air control unit, an exhaust air system can only be used when the window is open and the necessary supply air can flow into the room. A magnetic switch on the window sash monitors whether the window is open or closed and transmits this information to the control unit via a thin cable. This releases the power supply only when the window is tilted or open.
Mounting
The control line is connected to the control unit and the magnetic switch. Ideal for retrofitting if the control line has already been laid (2 cores, cable length max. 25m). The control unit is equipped with a potential-free changeover contact and can thus be interconnected in the fan motor supply line of the cooker hood so that the lighting of the cooker hood functions independently of the window position. All connection examples of the FDS 100
Second window (OR)
At least one window must be open so that the exhaust air system can be switched on. For this purpose, the KDS 110 SET is connected to the cable solenoid switch KMS 098K22 for the second window.
Second window (AND)
Two windows must be open at the same time so that the exhaust air system can be switched on. Two independent KDS 110 SETs are required for this purpose. The relays of the control units must be connected in series.
KDS 110 combined with Exhaust gas temperature monitor ATW-519
As soon as the exhaust gas temperature in the exhaust pipe exceeds 40°C, the window must be opened:
Performance features
- TÜV-tested with DIBt approval Z-85.2-14 (KDS 110)
- Terminal connection to control unit and magnetic switch
- Relay contact 5 A, potential-free changeover contact
- 4 spacer plates for magnetic switches as height compensation to the window sash
- Can be combined with second magnetic switch
- Expandable with additional magnetic switch for second window
- Lighting of the extractor bonnet also works when the window is closed, if only the motor supply line is switched
Areas of application:
- Fume cupboard control
- Bathroom fan control
Scope of delivery
- 1x control unit
- 1x cable magnetic switch
- 1x control cable 6 m
- 4x spacer plates for magnet
- Mounting material
- Detailed operating and assembly instructions
Color telegrey, transmitter housing also available on request in various RAL colors available against surcharge!
Technical data
Operating voltage: | 230 V AC / 50 Hz / approx. 1.8 VA |
Switching capacity KDS 110: | 1150 VA (700 W) / 5 A (3 A) |
Switching capacity KDS 116: | 3500 VA (2300 W) / 16 A (10 A) |
Control voltage: | 18 V |
Control line: | 6m / 2 x 0,14mm² | extendable up to 25 meters |
Functional area: | -15° C / +40° C |
Protection class: | IP 20 |
Control unit (HxWxD): | 51x51x26 mm |
Magnetic switch (HxWxD): | 55x15x18 mm |
Magnet (HxWxD): | 55x15x18 mm |
Spacer plate (HxWxD): | 55x15x5 mm |
Connection examples
Example 1 | |
When the window is closed, the control unit switches the socket of the cooker bonnet off. The control unit can be surface-mounted or flush-mounted in a distribution box, switch box or socket with a minimum diameter of 60 mm. If necessary, the fastening lugs on the side of the control unit can be broken away. | |
KDS 110 combined with integrated switch contact on window | |
With the KDS 110, a cable breakage protection (10 KOhm resistor) is integrated in the supplied cable magnetic switch. If the KDS 110 is not used with the original cable magnetic switch, but with an integrated switching contact on the window, the following must be observed: In order to maintain the cable break protection, you must connect the supplied 10 KOhm resistor parallel to the make contact according to the connection example. | |
Example 2 | |
On older cooker bonnets with mechanical fan speed control, the control unit is interposed in the fan motor supply line so that the lighting of the cooker bonnet functions independently of the window position. | |
Example 3 | |
Some cooker hood manufacturers offer external connection modules for separate control of the fan motor, e.g. BORA Professional Home In, Miele PUR 98, Miele KMDA7774, and many more. This can be realized with the potential-free relay of the KDS 110 control unit. | |
Example 4 | |
Functional description: | |
If there is no combustion in the fireplace, the exhaust air system can be switched on independently of the window position. As soon as the exhaust gas temperature in the exhaust pipe exceeds 40°C, the window must be opened. Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are significant regional differences, on which Elektrotechnik Schabus has no influence. The description of the flue gas temperature monitor with 10k resistor (Art. No. 201753) |
Example BORA
Connectionssample BORA Basic BIA | BHA | ...
|
WEEE NO.: EN91394868
Good material condition. First function check ok.