  • Mini float switch= Accessories forSCHABUS water detector SHT 5000 and 5001, 5002
  • for water level reportingLevel height min. 4 cm, e.g. in tanks, cisterns, wells, pump sumps and much more.
  • particularly suitableSalt water and chlorinated media| also suitable for food or other media to which stainless steel is resistant, for all liquids with a density of at least 0.7 g/cm³, e.g. water, heating oil, diesel, vegetable oil, lubricating oils, etc.
  • Material completely made ofV4A stainless steel, shaft turned and milled from solid
  • Reed contact soldered to cable and with Wepuran®cast, cable length 2.5 m – special lengths on request
  • Opener (NC) / closer (NO) – Turning the float body corresponds to the reversed contact function, not required for changeover contacts
  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 300939

Delivery time: 2-3 working days

View full details
Mini float switch V4A changeover contact

Mini float switch V4A changeover contact

102,94 €
  • Description
  • Technical information
  • Downloads
  • FAQ - Frequently Asked Questions
  • Reviews

Scope of delivery

  • Mini float switch – plastic
  • cast on 2.5 meters LIYY control cable 3 x 0.14 mm²
  • Operating instructions for water sensors | float switches | accessories

🧪 Highest corrosion resistance – even in pool water, salt water, etc.

The compact mini float switches made of V4A stainless steel are ideal for applications with particularly aggressive or chlorinated liquids – for example, in chlorinated pool water, salt water, or weak chemical alkalis. Compared to V2A, V4A offers even greater corrosion resistance thanks to the addition of molybdenum and titanium. This makes the float switch suitable for use in environments where V2A reaches its limits.


⚙️ Durable thanks to precise manufacturing

The shaft of the float switch is milled and turned from solid V4A stainless steel, making it extremely stable – even under constant stress. The float body is made of thin, also rust-proof V4A sheet metal. Inside, a high-quality reed contact from Meder, which is watertightly cast into the shaft and firmly soldered, ensures permanently reliable signal transmission.


🔁 Extremely durable & maintenance-free

Combined with low switching power – less than 5 volts and 1 milliampere – the float switch achieves a service life of up to one trillion switching cycles. This means no mechanical wear, no maintenance, and no failures. Once installed, the switch operates precisely and reliably over the long term – even in confined spaces.


🔌 Connection cable included

The float switch is equipped as standard with a 2.5-meter-long LiYY/PVC cable. According to the manufacturer, this cable is temporarily waterproof, flame-retardant, self-extinguishing, and highly resistant to oils, greases, coolants, and lubricants.


🌊 Suitable for demanding liquids

The float switch works reliably with all liquids with a density of 0.7 g/cm³ or higher. Depending on the installation position, it can be operated as a normally open (NO) or normally closed (NC) contact – simply by turning the float. This step is not necessary for versions with an integrated changeover contact, as both functions are already integrated.


🧩 Installation with suitable accessories

For reliable operation, we recommend the optionally available mounting bracket (item no. 300787). The mounting bracket ensures the float switch is positioned as vertically as possible, with a maximum deviation of 30°, so the float can slide freely on the shaft without jamming or jamming.


⚙️ Technical note & connection

🔌 Connection to the following water detectors required (please order separately):
SHT 5000, SHT 5001 or level controller SHT 5002 from Elektrotechnik Schabus.
Cabling via thin, unshielded LiYY control cable (3 × 0.14 mm²) – max. 50 m cable length per scanner.

📏 Cable extension up to 50 meters possible
The factory-installed cable length can be extended up to 50 m . The recommended cross-section is 3 × 0.14 mm² .


⚠️ Notes on cable routing and area of ​​application
The LIYY cables used are only temporarily waterproof and, according to the manufacturer , are flame-retardant, low-adhesion, and self-extinguishing . They are resistant to oils, greases, coolants, and lubricants , but are not suitable for permanent water contact.

⚠️ Safety note: The LIYY cables must never be laid parallel to 230 V mains cables to avoid interference and safety risks.

⚠️ What do I need to consider when connecting the electrical system?

IMPORTANT SAFETY NOTICE:
An incorrect electrical connection can destroy the sensitive reed contacts and thus cause a malfunction – in the worst case, resulting in personal injury or property damage.

Please therefore note:

  • No direct connection to inductive loads (e.g. relays, solenoid valves)

  • No direct connection to capacitive loads (e.g. PLC/PCS – see our “active” water sensors and float switches) or long cables > 50 m

  • Permissible switching capacity must not be exceeded

👉 For inductive loads, protection by means of an RC element or freewheeling diode is mandatory.

RC elements for reed contacts 10 ... 40 VAVoltageResistanceCapacitanceRC element typeAC 24 V100 Ω0.33 μFA 3/24

WEEE NO.: DE91394868

Operating voltage max. 25 V AC / 60 V DC / 0.5 A
Switching capacity max. 10 watts
Protection class IP68
Relay contact Normally closed (NC) / normally open (NO)
Line 3 x 0.14 mm² LIYY cable, 2.5 meters
material Connection thread V4A stainless steel, shaft made of solid V4A stainless steel turned and milled, shaft V4A stainless steel, Ø 8.3 mm, 62.8 mm long
medium min. 0.7g/cm³ density, pressureless
Assembly Installation position vertical, max. ±30° inclination, mounting angle

🔧How is the float switch installed?
The V4A stainless steel float switch is ideally mounted with a suitable mounting bracket (item no. 300787) to ensure the most vertical alignment possible with a maximum deviation of 30°. This is the only way the float can slide freely and reliably on the shaft.

↕️Can I reverse the switching function?
No, this is not necessary with the changer.
The integrated changeover contact providesalways both switching functions at the same time– Normally closed (NC)andNormally open (NO).
This eliminates the need to turn the float. The signal is simply picked up via the corresponding wire in the connecting cable.

💧For which media is the float switch suitable?
The V4A float switch is suitable for all liquids with a density of at least 0.7 g/cm³ – even under demanding conditions. Thanks to the particularly corrosion-resistant stainless steel alloy, it can be used even inchlorinated pool water, salt water or weak chemical alkalisThis is easily possible. It's also ideal for hygienically sensitive environments such as food processing.

🔌Is the connection cable replaceable?
The device comes standard with a 2.5 m long LiYY/PVC cable. This is flame-retardant, temporarily waterproof, and chemical-resistant. Custom lengths are also available upon request – our Technical Support team will be happy to advise you.

⚠️What do I need to consider when connecting the electrical system?

IMPORTANT SAFETY NOTICE:
An incorrect electrical connection can destroy the sensitive reed contacts and thus cause a malfunction – in the worst case, resulting in personal injury or property damage.

Please therefore note:

  • No direct connection to inductive loads (e.g. relays, solenoid valves)
  • No direct connection to capacitive loads (e.g. PLC/PCS – see our “active” water sensors and float switches) or long cables > 50 m
  • Permissible switching capacity must not be exceeded

👉 For inductive loads, protection by means of an RC element or freewheeling diode is mandatory.

Recommended RC elements for reed contacts (10 – 40 VA):

VoltageResistanceCapacitanceTypeAC 24 V100 Ω0.33 μFA 3/24

If you are unsure, please speak to a qualified electrician or contact our support team directly.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description

Scope of delivery

  • Mini float switch – plastic
  • cast on 2.5 meters LIYY control cable 3 x 0.14 mm²
  • Operating instructions for water sensors | float switches | accessories

🧪 Highest corrosion resistance – even in pool water, salt water, etc.

The compact mini float switches made of V4A stainless steel are ideal for applications with particularly aggressive or chlorinated liquids – for example, in chlorinated pool water, salt water, or weak chemical alkalis. Compared to V2A, V4A offers even greater corrosion resistance thanks to the addition of molybdenum and titanium. This makes the float switch suitable for use in environments where V2A reaches its limits.


⚙️ Durable thanks to precise manufacturing

The shaft of the float switch is milled and turned from solid V4A stainless steel, making it extremely stable – even under constant stress. The float body is made of thin, also rust-proof V4A sheet metal. Inside, a high-quality reed contact from Meder, which is watertightly cast into the shaft and firmly soldered, ensures permanently reliable signal transmission.


🔁 Extremely durable & maintenance-free

Combined with low switching power – less than 5 volts and 1 milliampere – the float switch achieves a service life of up to one trillion switching cycles. This means no mechanical wear, no maintenance, and no failures. Once installed, the switch operates precisely and reliably over the long term – even in confined spaces.


🔌 Connection cable included

The float switch is equipped as standard with a 2.5-meter-long LiYY/PVC cable. According to the manufacturer, this cable is temporarily waterproof, flame-retardant, self-extinguishing, and highly resistant to oils, greases, coolants, and lubricants.


🌊 Suitable for demanding liquids

The float switch works reliably with all liquids with a density of 0.7 g/cm³ or higher. Depending on the installation position, it can be operated as a normally open (NO) or normally closed (NC) contact – simply by turning the float. This step is not necessary for versions with an integrated changeover contact, as both functions are already integrated.


🧩 Installation with suitable accessories

For reliable operation, we recommend the optionally available mounting bracket (item no. 300787). The mounting bracket ensures the float switch is positioned as vertically as possible, with a maximum deviation of 30°, so the float can slide freely on the shaft without jamming or jamming.


⚙️ Technical note & connection

🔌 Connection to the following water detectors required (please order separately):
SHT 5000, SHT 5001 or level controller SHT 5002 from Elektrotechnik Schabus.
Cabling via thin, unshielded LiYY control cable (3 × 0.14 mm²) – max. 50 m cable length per scanner.

📏 Cable extension up to 50 meters possible
The factory-installed cable length can be extended up to 50 m . The recommended cross-section is 3 × 0.14 mm² .


⚠️ Notes on cable routing and area of ​​application
The LIYY cables used are only temporarily waterproof and, according to the manufacturer , are flame-retardant, low-adhesion, and self-extinguishing . They are resistant to oils, greases, coolants, and lubricants , but are not suitable for permanent water contact.

⚠️ Safety note: The LIYY cables must never be laid parallel to 230 V mains cables to avoid interference and safety risks.

⚠️ What do I need to consider when connecting the electrical system?

IMPORTANT SAFETY NOTICE:
An incorrect electrical connection can destroy the sensitive reed contacts and thus cause a malfunction – in the worst case, resulting in personal injury or property damage.

Please therefore note:

  • No direct connection to inductive loads (e.g. relays, solenoid valves)

  • No direct connection to capacitive loads (e.g. PLC/PCS – see our “active” water sensors and float switches) or long cables > 50 m

  • Permissible switching capacity must not be exceeded

👉 For inductive loads, protection by means of an RC element or freewheeling diode is mandatory.

RC elements for reed contacts 10 ... 40 VAVoltageResistanceCapacitanceRC element typeAC 24 V100 Ω0.33 μFA 3/24

WEEE NO.: DE91394868

Technical information
Operating voltage max. 25 V AC / 60 V DC / 0.5 A
Switching capacity max. 10 watts
Protection class IP68
Relay contact Normally closed (NC) / normally open (NO)
Line 3 x 0.14 mm² LIYY cable, 2.5 meters
material Connection thread V4A stainless steel, shaft made of solid V4A stainless steel turned and milled, shaft V4A stainless steel, Ø 8.3 mm, 62.8 mm long
medium min. 0.7g/cm³ density, pressureless
Assembly Installation position vertical, max. ±30° inclination, mounting angle
Connection examples
FAQ - Frequently Asked Questions

🔧How is the float switch installed?
The V4A stainless steel float switch is ideally mounted with a suitable mounting bracket (item no. 300787) to ensure the most vertical alignment possible with a maximum deviation of 30°. This is the only way the float can slide freely and reliably on the shaft.

↕️Can I reverse the switching function?
No, this is not necessary with the changer.
The integrated changeover contact providesalways both switching functions at the same time– Normally closed (NC)andNormally open (NO).
This eliminates the need to turn the float. The signal is simply picked up via the corresponding wire in the connecting cable.

💧For which media is the float switch suitable?
The V4A float switch is suitable for all liquids with a density of at least 0.7 g/cm³ – even under demanding conditions. Thanks to the particularly corrosion-resistant stainless steel alloy, it can be used even inchlorinated pool water, salt water or weak chemical alkalisThis is easily possible. It's also ideal for hygienically sensitive environments such as food processing.

🔌Is the connection cable replaceable?
The device comes standard with a 2.5 m long LiYY/PVC cable. This is flame-retardant, temporarily waterproof, and chemical-resistant. Custom lengths are also available upon request – our Technical Support team will be happy to advise you.

⚠️What do I need to consider when connecting the electrical system?

IMPORTANT SAFETY NOTICE:
An incorrect electrical connection can destroy the sensitive reed contacts and thus cause a malfunction – in the worst case, resulting in personal injury or property damage.

Please therefore note:

  • No direct connection to inductive loads (e.g. relays, solenoid valves)
  • No direct connection to capacitive loads (e.g. PLC/PCS – see our “active” water sensors and float switches) or long cables > 50 m
  • Permissible switching capacity must not be exceeded

👉 For inductive loads, protection by means of an RC element or freewheeling diode is mandatory.

Recommended RC elements for reed contacts (10 – 40 VA):

VoltageResistanceCapacitanceTypeAC 24 V100 Ω0.33 μFA 3/24

If you are unsure, please speak to a qualified electrician or contact our support team directly.