• GX-CO2-30 carbon dioxide gas sensor
  • GX-CO2-30 carbon dioxide gas sensor
  • GX-CO2-30 carbon dioxide gas sensor
  • GX-CO2-30 carbon dioxide gas sensor
  • GX-CO2-30 carbon dioxide gas sensor
  • GX-CO2-30 carbon dioxide gas sensor

GX-CO2-30 carbon dioxide gas sensor

GX-CO2-30 carbon dioxide gas sensor

Regular price 200,84 €
Regular price Sale price 200,84 €
Sale Sold out
Taxes included. Versandkosten
  • optimized as an accessory - external sensor - for the SCHABUSGas detectors GX-HS and GX-A1+
  • Measuring principle:NDIR(non-dispersive infrared measurement technology) – durable and precise
  • asactive sensor also mobile Can be used without a gas detector
  • optical alarmthrough LED displays for operation, fault, alarm directly on the sensor,acoustic alarmintegrated buzzer for direct alarm messages
  • Detection ofCarbon dioxide (CO2)in beverage dispensing systems, wine cellars and all gas systems with CO2 from bottles, including dry ice storage, cold storage rooms and storage rooms with CO₂ pressure bottles, catering establishments with beverage dispensing systems, breweries, beverage logistics and bottling plants, technical rooms with CO₂ systems under pressure, food production with CO₂ atmosphere, research laboratories with CO₂ technology, commercial kitchens and canteens
  • Alarm thresholds according to the Beverage Dispensing Ordinance:Pre-alarm triggered at 2.5% volume concentration, main alarm triggered at 3% volume concentration
  • Protection class IP 54 - Splash-proof, with integrated high-tech membrane
  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 300315

Delivery time: 2-3 working days

View full details
GX-CO2-30 carbon dioxide gas sensor

GX-CO2-30 carbon dioxide gas sensor

200,84 €
  • Description
  • Technical information
  • Downloads
  • Reviews
Scope of delivery
  • Gas sensor with molded cable
  • 6 m cable, white, 3x0.14 mm²
  • 2 mounting screws and dowels
  • detailed operating instructions with assembly instructions
External CO2 sensor for carbon dioxide - from technical systems

The external CO2 sensor, with its own alarm, status LEDs, and test button, is optimized as an accessory for the SCHABUS GX-HS and GX-A1+ gas warning devices . Its warning levels and IP54 protection rating comply with the German Beverage Dispensing Equipment Ordinance . For use in the hospitality industry, this NDIR sensor is designed with an alarm threshold of 1.5% vol. CO2 for the pre-alarm and 3.0% vol. CO2 for the main alarm.

The GX-CO2-30 CO₂ gas sensor from Elektrotechnik Schabus is specifically designed for use in cold storage rooms, warehouses, and areas with CO₂ pressure cylinders – especially in the hospitality industry, where CO₂ is widely used in beverage dispensing systems. It reliably monitors carbon dioxide from technical systems, thus supporting operators in the early detection of potential leaks in valves and pressure vessels.

In small, poorly ventilated rooms, even a small leak can cause CO₂ concentrations to reach dangerous levels within a short period of time. The GX-CO2-30 reliably detects such conditions – without reacting excessively to stale or poorly ventilated room air. For this reason, the alarm thresholds are set higher than those of typical indoor air sensors, as is practical: the pre-alarm is triggered at 1.5% vol. CO₂, and the main alarm at 3.0% vol. CO₂. These settings take into account the special requirements of technical systems with pressurized CO₂, but are deliberately geared towards everyday suitability and the avoidance of false alarms.

The sensor uses a precise NDIR (non-dispersive infrared) measurement principle for reliable carbon dioxide detection. As an active sensor, it also operates independently—with its own status indicator, integrated alarm, and test button—and can also be combined with the GX-HS and GX-A1+ gas detectors. Communication is via an analog voltage signal, which can trigger a potential-free relay switching in the detector when the alarm threshold is exceeded. This allows for easy, flexible integration into ventilation, alarm, or control systems.

For harsh operating environments, the sensor housing has an IP54 protection rating – protected against dust deposits inside and water splashes from all sides. An integrated high-tech membrane further protects the sensitive electronics from moisture, for example, when cleaning rooms. The sensor can therefore remain installed and does not need to be removed for routine cleaning procedures.

Important: The GX-CO2-30 meets essential requirements of the Technical Rules for Hazardous Substances (TRGS) for beverage dispensing systems, but is not certified as a complete replacement for a TRGS-compliant system. It offers maximum compatibility with the proven SCHABUS systems and is ideally suited as a practical warning system for restaurants, food processing facilities, and technical operating rooms with CO₂ applications.

Typical areas of application

  • Cold rooms and storage rooms with CO₂ pressure cylinders
  • Restaurants with beverage dispensing systems
  • Breweries, beverage logistics and bottling plants
  • Technical rooms with pressurized CO₂ systems
  • Food production with CO₂ atmosphere
  • Research laboratories with CO₂ technology
  • Large kitchens and canteens
Extension of the connecting cable The sensor's connecting cable can be extended. The following minimum cross-sections apply depending on the cable length: Cable cross-section 3 x 0.14 mm²: maximum length 20 m Cable cross-section 3 x 0.5 mm²: maximum length 50 m WEEE NO.: DE91394868
Operating voltage 12-24 Volt DC (battery)
Functional area 0°C – 50°C / 10-90% rH
Protection class IP54
Line 6 m | 3×0.14mm2 | white
humidity 10% – 90% rH, non-condensing
Trigger concentration Main alarm 3% 30,000 ppm CO2, pre-alarm 1.5% 15,000 ppm CO2
Sound pressure level 85 dB(A) @ 1m
sensor NDIR Infrared
temperature -20°C / + 60°C storage temperature

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description
Scope of delivery
  • Gas sensor with molded cable
  • 6 m cable, white, 3x0.14 mm²
  • 2 mounting screws and dowels
  • detailed operating instructions with assembly instructions
External CO2 sensor for carbon dioxide - from technical systems

The external CO2 sensor, with its own alarm, status LEDs, and test button, is optimized as an accessory for the SCHABUS GX-HS and GX-A1+ gas warning devices . Its warning levels and IP54 protection rating comply with the German Beverage Dispensing Equipment Ordinance . For use in the hospitality industry, this NDIR sensor is designed with an alarm threshold of 1.5% vol. CO2 for the pre-alarm and 3.0% vol. CO2 for the main alarm.

The GX-CO2-30 CO₂ gas sensor from Elektrotechnik Schabus is specifically designed for use in cold storage rooms, warehouses, and areas with CO₂ pressure cylinders – especially in the hospitality industry, where CO₂ is widely used in beverage dispensing systems. It reliably monitors carbon dioxide from technical systems, thus supporting operators in the early detection of potential leaks in valves and pressure vessels.

In small, poorly ventilated rooms, even a small leak can cause CO₂ concentrations to reach dangerous levels within a short period of time. The GX-CO2-30 reliably detects such conditions – without reacting excessively to stale or poorly ventilated room air. For this reason, the alarm thresholds are set higher than those of typical indoor air sensors, as is practical: the pre-alarm is triggered at 1.5% vol. CO₂, and the main alarm at 3.0% vol. CO₂. These settings take into account the special requirements of technical systems with pressurized CO₂, but are deliberately geared towards everyday suitability and the avoidance of false alarms.

The sensor uses a precise NDIR (non-dispersive infrared) measurement principle for reliable carbon dioxide detection. As an active sensor, it also operates independently—with its own status indicator, integrated alarm, and test button—and can also be combined with the GX-HS and GX-A1+ gas detectors. Communication is via an analog voltage signal, which can trigger a potential-free relay switching in the detector when the alarm threshold is exceeded. This allows for easy, flexible integration into ventilation, alarm, or control systems.

For harsh operating environments, the sensor housing has an IP54 protection rating – protected against dust deposits inside and water splashes from all sides. An integrated high-tech membrane further protects the sensitive electronics from moisture, for example, when cleaning rooms. The sensor can therefore remain installed and does not need to be removed for routine cleaning procedures.

Important: The GX-CO2-30 meets essential requirements of the Technical Rules for Hazardous Substances (TRGS) for beverage dispensing systems, but is not certified as a complete replacement for a TRGS-compliant system. It offers maximum compatibility with the proven SCHABUS systems and is ideally suited as a practical warning system for restaurants, food processing facilities, and technical operating rooms with CO₂ applications.

Typical areas of application

  • Cold rooms and storage rooms with CO₂ pressure cylinders
  • Restaurants with beverage dispensing systems
  • Breweries, beverage logistics and bottling plants
  • Technical rooms with pressurized CO₂ systems
  • Food production with CO₂ atmosphere
  • Research laboratories with CO₂ technology
  • Large kitchens and canteens
Extension of the connecting cable The sensor's connecting cable can be extended. The following minimum cross-sections apply depending on the cable length: Cable cross-section 3 x 0.14 mm²: maximum length 20 m Cable cross-section 3 x 0.5 mm²: maximum length 50 m WEEE NO.: DE91394868
Technical information
Operating voltage 12-24 Volt DC (battery)
Functional area 0°C – 50°C / 10-90% rH
Protection class IP54
Line 6 m | 3×0.14mm2 | white
humidity 10% – 90% rH, non-condensing
Trigger concentration Main alarm 3% 30,000 ppm CO2, pre-alarm 1.5% 15,000 ppm CO2
Sound pressure level 85 dB(A) @ 1m
sensor NDIR Infrared
temperature -20°C / + 60°C storage temperature
Connection examples
FAQ - Frequently Asked Questions