View full detailsFunctional description: All gas-powered appliances have the potential to release hazardous gases. As soon as the GX-HS gas detector detects such gases, it automatically cuts off the power supply and, optionally, the gas supply through the gas line. Depending on the type of sensor connected, the device detects town gas and natural gas (methane/butane), coolants and refrigerants, or carbon dioxide used in the catering industry or from the air we breathe.
The GX-HS device provides an output for an external buzzer. The input also offers two configuration options (via wire jumper). One option is to save the triggered alarm and acknowledge it by pressing a button. The other option is to automatically clear the alarm when the gas concentration falls below the set value.
Gas sensor connection: In principle, only a single gas sensor can be connected to the GX-HS gas detector.
Applications depending on the sensor
Type Gases Ref. No. GX-SE Town and natural gas (methane, butane, propane) 200897 GX-CFC Chlorofluorocarbons, refrigerant R-32 and similar 200901 GX-DS Carbon dioxide, indoor air quality, simple 200884 GX-CO2-25 Carbon dioxide, indoor air quality, with test function 200989 GX-CO2-30 Carbon dioxide from processes and technical systems 300315 GX-CO Carbon monoxide, flue gases 2 00898
Accessories can be found under: Warning Systems Accessories
Features
Technical data
Operating voltage GX-HS 24V: 12 - 24 V DC from rechargeable batteries / batteries Power consumption: 3 - 5 VA, depending on operating condition Relay contact: 2 changeover contacts NC/NO (potential-free) Switching capacity: max. 5 A / 230 V Sensor connection: 1 Sensor voltage: 5 V Buzzer connection: 9 - 12 V= / 50 mA Operating range: -15 °C / +40 °C Protection class: IP 20 Dimensions (HxWxD): 57 x 72 x 90 mm
WEEE No.: 91394868
Protection class | IP67 |
---|
Functional description: All gas-powered appliances have the potential to release hazardous gases. As soon as the GX-HS gas detector detects such gases, it automatically cuts off the power supply and, optionally, the gas supply through the gas line. Depending on the type of sensor connected, the device detects town gas and natural gas (methane/butane), coolants and refrigerants, or carbon dioxide used in the catering industry or from the air we breathe.
The GX-HS device provides an output for an external buzzer. The input also offers two configuration options (via wire jumper). One option is to save the triggered alarm and acknowledge it by pressing a button. The other option is to automatically clear the alarm when the gas concentration falls below the set value.
Gas sensor connection: In principle, only a single gas sensor can be connected to the GX-HS gas detector.
Applications depending on the sensor
Type Gases Ref. No. GX-SE Town and natural gas (methane, butane, propane) 200897 GX-CFC Chlorofluorocarbons, refrigerant R-32 and similar 200901 GX-DS Carbon dioxide, indoor air quality, simple 200884 GX-CO2-25 Carbon dioxide, indoor air quality, with test function 200989 GX-CO2-30 Carbon dioxide from processes and technical systems 300315 GX-CO Carbon monoxide, flue gases 2 00898
Accessories can be found under: Warning Systems Accessories
Features
Technical data
Operating voltage GX-HS 24V: 12 - 24 V DC from rechargeable batteries / batteries Power consumption: 3 - 5 VA, depending on operating condition Relay contact: 2 changeover contacts NC/NO (potential-free) Switching capacity: max. 5 A / 230 V Sensor connection: 1 Sensor voltage: 5 V Buzzer connection: 9 - 12 V= / 50 mA Operating range: -15 °C / +40 °C Protection class: IP 20 Dimensions (HxWxD): 57 x 72 x 90 mm
WEEE No.: 91394868
Protection class | IP67 |
---|