View full detailsScope of delivery
Housing of the window magnetic switch in color telegrey-4 available on request in all RAL colors for an additional charge.
Include your chimney sweep in your planning before installation to ensure that nothing stands in the way of inspection afterward. There are significant regional differences, over which Elektrotechnik Schabus has no influence.
Safe exhaust air control for individual furnaces – automatic, radio-based and intrinsically safe.
The set, consisting of the FTW 519 wireless temperature monitor and the FDS 100 wireless exhaust air control, reliably ensures that your exhaust air system is only activated under safe operating conditions . The integrated temperature monitoring system in the flue pipe detects whether the stove is hot or not.
The included window transmitter ensures that the exhaust air system is activated when the window is open (and the stove is active). Ideal for individual fireplaces such as Swedish stoves or wood-burning stoves.
Wireless communication : FTW transmitter and window transmitter transmit to the FDS receiver
Intrinsically safe system : mechanical sensor defects lead to automatic blocking
Safe temperature monitoring : Release only when the oven is cold or the window is open
Approval : DIBt certification applies to the included radio exhaust air control
Expandable : additional window transmitter or second receiver possible
The temperature sensor in the flue pipe detects whether the stove's temperature exceeds the limit of 40°C. If this is the case, the exhaust air system is blocked. If the temperature drops by approximately 15°C, it is enabled again.
Mechanical damage to the sensor automatically lowers the switching point – this makes the system fail-safe .
Additionally: The window contact transmitter allows the exhaust air to be released when the oven is hot – but a window is opened.
The FTW 519 is mounted directly on the visible (uncovered) flue pipe (Ø at least 120 mm) using a flange. The minimum distance from the stove edge is 80 cm.
Free air flow through the room is required
Not suitable for stove pipes behind cladding or heat-dissipating parts
Max. temperature on the FTW transmitter : 65 °C
🛑 Important : The sensor must not be bent or damaged during installation.
Would you like to be able to choose between two windows?
With a second window contact transmitter FDS 098 (same code, factory-programmed) an OR function can be implemented – an open window is sufficient.
Would you like to control another device?
Add a second receiver ( FDS 199 or FDS 299 ). As soon as the stove cools down or a window is opened, both receivers will activate the exhaust system.
👉 Please provide the serial number of your existing receiver when ordering.
The FTW 519 is only permitted for use with a single furnace . It is not safe enough to use multiple furnaces.
👉 In this case, please contact our technical support to find a suitable solution.
WEEE NO.: DE91394868
Protection class | IP20 |
---|---|
radio frequency | 868 MHz SRD |
battery | CR2023/ 3 V |
Dimensions (W x W x D) | 183x68x85mm , receiver 53x53x31mm |
Assembly | Assembly |
Switching differential | approx. 15 K, hysteresis |
Switching accuracy | +/- 7 K |
Switching point | 40° C, factory set |
Technical data of related articles | 300268 FDS 100 |
temperature | 65 °C switch housing temperature, max. 180 °C ambient temperature, max. 500 °C sensor temperature |
transmission | radio |
Scope of delivery
Housing of the window magnetic switch in color telegrey-4 available on request in all RAL colors for an additional charge.
Include your chimney sweep in your planning before installation to ensure that nothing stands in the way of inspection afterward. There are significant regional differences, over which Elektrotechnik Schabus has no influence.
Safe exhaust air control for individual furnaces – automatic, radio-based and intrinsically safe.
The set, consisting of the FTW 519 wireless temperature monitor and the FDS 100 wireless exhaust air control, reliably ensures that your exhaust air system is only activated under safe operating conditions . The integrated temperature monitoring system in the flue pipe detects whether the stove is hot or not.
The included window transmitter ensures that the exhaust air system is activated when the window is open (and the stove is active). Ideal for individual fireplaces such as Swedish stoves or wood-burning stoves.
Wireless communication : FTW transmitter and window transmitter transmit to the FDS receiver
Intrinsically safe system : mechanical sensor defects lead to automatic blocking
Safe temperature monitoring : Release only when the oven is cold or the window is open
Approval : DIBt certification applies to the included radio exhaust air control
Expandable : additional window transmitter or second receiver possible
The temperature sensor in the flue pipe detects whether the stove's temperature exceeds the limit of 40°C. If this is the case, the exhaust air system is blocked. If the temperature drops by approximately 15°C, it is enabled again.
Mechanical damage to the sensor automatically lowers the switching point – this makes the system fail-safe .
Additionally: The window contact transmitter allows the exhaust air to be released when the oven is hot – but a window is opened.
The FTW 519 is mounted directly on the visible (uncovered) flue pipe (Ø at least 120 mm) using a flange. The minimum distance from the stove edge is 80 cm.
Free air flow through the room is required
Not suitable for stove pipes behind cladding or heat-dissipating parts
Max. temperature on the FTW transmitter : 65 °C
🛑 Important : The sensor must not be bent or damaged during installation.
Would you like to be able to choose between two windows?
With a second window contact transmitter FDS 098 (same code, factory-programmed) an OR function can be implemented – an open window is sufficient.
Would you like to control another device?
Add a second receiver ( FDS 199 or FDS 299 ). As soon as the stove cools down or a window is opened, both receivers will activate the exhaust system.
👉 Please provide the serial number of your existing receiver when ordering.
The FTW 519 is only permitted for use with a single furnace . It is not safe enough to use multiple furnaces.
👉 In this case, please contact our technical support to find a suitable solution.
WEEE NO.: DE91394868
Protection class | IP20 |
---|---|
radio frequency | 868 MHz SRD |
battery | CR2023/ 3 V |
Dimensions (W x W x D) | 183x68x85mm , receiver 53x53x31mm |
Assembly | Assembly |
Switching differential | approx. 15 K, hysteresis |
Switching accuracy | +/- 7 K |
Switching point | 40° C, factory set |
Technical data of related articles | 300268 FDS 100 |
temperature | 65 °C switch housing temperature, max. 180 °C ambient temperature, max. 500 °C sensor temperature |
transmission | radio |