• Cable exhaust air control with thermal switch KDT 210
  • Cable exhaust air control with thermal switch KDT 210
  • Cable exhaust air control with thermal switch KDT 210
  • Cable exhaust air control with thermal switch KDT 210

Cable exhaust air control with thermal switch KDT 210

Cable exhaust air control with thermal switch KDT 210

Normal price 249,00 €
Normal price Selling price 249,00 €
Sale Sold out
including VAT plus Versandkosten
  • KDT 210 Kabel-Abluftsteuerung mit Thermoschalter 40°C für Dunstabzugssteuerung und Abluftsteuerung
  • Komfortlösung: Fenster muss nur geöffnet werden wenn der Ofen in Betrieb ist
  • zur Montage an frei zugänglichem Stück Ofenrohr
  • einfache Installation durch Aufputzleitungen
  • TÜV geprüft (ohne DIBt-Zertifikat)
  • 2x 6 Meter Steuer- und Silikonleitung vormontiert, inkl. Kabelbruchsicherung

Involve your chimney sweep in your planning before installation so that nothing stands in the way of acceptance afterwards. There are clear regional differences over which Elektrotechnik Schabus has no influence.

  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

Item number: 300674

Delivery time: 2-3 working days

View full details
Cable exhaust air control with thermal switch KDT 210

Cable exhaust air control with thermal switch KDT 210

249,00 €
  • Description
  • Technical information
  • Downloads
  • FAQ - Frequently asked questions
  • Reviews
Scope of delivery
  • Control unit with 6 m control cable
  • Thermal switch with 6 m silicone cable
  • Cable magnetic switch
  • 4 spacer plates for magnet/transmitter (for height adjustment when mounting on the window or window frame)
  • Mounting material
  • Operating instructions
The KDS 210 cable exhaust control set, which does not require DIBt approval, consists of a magnetic window switch with an intermediate plug for the control unit and an ATW 519 flue gas temperature monitor with integrated cable break protection for a free and readily accessible section of stovepipe. All components are pre-assembled. The additional temperature switch allows the exhaust system to operate independently of the window position as long as the stove is cold; opening the window is only necessary when the stove is in use. The control unit is simply plugged between the socket and the extractor hood's power plug. The power plug lock prevents the extractor hood's power plug from being accidentally plugged in. The control cables are installed on the window contact switch and the thermal switch. We recommend having this kit installed by a specialist company. The cables must be permanently mounted as surface-mounted cables. Second window The system can be combined with an additional KMS 098K22 cable magnetic switch for a second window. At least one window must then be open for the exhaust system to be activated while the furnace is in operation.

integrated window contact switch from the window manufacturer The KDT 210 includes a cable break protection device (10 kOhm resistor) integrated into the supplied cable magnetic switch. If the KDT 210 is not used with the original cable magnetic switch, but with an integrated switch contact on the window, the following must be observed: To maintain the cable break protection, you must connect the supplied 10 kOhm resistor in parallel with the normally open contact, as shown in the connection example. WEEE NO.: DE91394868
Operating voltage 230V AC/50Hz
Switching performance 1150 VA (700 W)/5A (3A)
Functional area -15°C/+40°C
Protection class IP40
TÜV tested TÜV tested
Dimensions(WxWxD)

Control unit 121x57x46 mm, magnet 55x15x18 mm, spacer plate 55x15x5 mm, magnetic switch 55x31x18 mm

Power consumption 18V
Line 6m | 2×0.14mm2 | white
Technical data of related items 201753 ATW 519

Technology & function

What does the KDT 210 cable exhaust air control do? The KDT 210 cable exhaust air control ensures safe operation of exhaust systems when a fireplace is being operated in the same room at the same time. The device uses a temperature sensor in the exhaust pipe to detect whether the fireplace (e.g. gas boiler, wood stove) is in operation. As soon as a preset temperature is exceeded, the KDT 210 cable exhaust air control automatically interrupts the power supply to the exhaust system - thus preventing dangerous negative pressure.

How does temperature monitoring work? A thermal switch is located on the fireplace's exhaust pipe. It triggers as soon as the exhaust gas temperature exceeds 40°C (fixed switching point). This information is transmitted via cable to the control unit, which then switches off the exhaust system.

Can I adjust the temperature? No. The trigger temperature is fixed at 40°C - a proven and safe value for detecting the ignition of fireplaces dependent on room air.

Installation

Where is the thermal switch installed? The thermal switch is attached directly to the fireplace's exhaust pipe - ideally with an included pipe clamp or mounting spring. The mounting point should be easily accessible and conduct heat so that the temperature is reliably recorded.

6 meter connection cable is not enough – what can I do? The pre-assembled cables of the KDT 210 set can be extended up to 25 meters using standard two-core cables. However, it should be noted that the KDT 210 is designed as an easy-to-install complete set for easy installation. For larger distances, it is recommended to use the more flexible individual components - such as the KDS 110 control unit in combination with the exhaust gas temperature monitor (item no. 201753).
The temperature sensor is integrated directly into the window contact cable by separating a wire and connecting the sensor in between - a proven solution for longer cable routes or individual planning.

Important note on maintenance: The sensor of the exhaust gas temperature monitor is extremely sensitive to mechanical stress. Please make sure the sensor before cleaning the smoke pipe - especially by a chimney sweep - it is essential to remove it from the pipe. In this way you avoid damage and ensure the long-term functional reliability of the system.

Legal

Does the KDT 210 cable exhaust air control meet the requirements of the combustion regulations? Yes, the device is suitable for use in conjunction with indoor air-dependent fireplaces. It meets the requirements of many state combustion regulations for protection against exhaust gas backflow due to negative pressure. see Fireplace Ordinance (§4 Abs. 2 FeuVo) 

Is the device DIBt approved? No. The KDT 210 cable exhaust air control does not have DIBt approval. If your chimney sweep or the building authority requires approval, you should use an approved model such as the KDS 110 or the KDS 210 set.

purchase & service

Can I install the system myself? The mechanical part (assembly of the thermal switch) can be done yourself with a little technical understanding. However, the electrical installation should always be carried out by a trained electrician.

What happens if the thermal switch breaks? The thermal switch is a proven, purely mechanical component. Should it still fail, the exhaust system remains permanently blocked - a certain malfunction. Replacement is available as an accessory.

Where can I get spare parts or accessories? Accessories such as additional thermal switches or pipe clamps can be obtained directly from Elektrotechnik Schabus or from specialist retailers. Please have the article number or serial number of your device ready.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description
Scope of delivery
  • Control unit with 6 m control cable
  • Thermal switch with 6 m silicone cable
  • Cable magnetic switch
  • 4 spacer plates for magnet/transmitter (for height adjustment when mounting on the window or window frame)
  • Mounting material
  • Operating instructions
The KDS 210 cable exhaust control set, which does not require DIBt approval, consists of a magnetic window switch with an intermediate plug for the control unit and an ATW 519 flue gas temperature monitor with integrated cable break protection for a free and readily accessible section of stovepipe. All components are pre-assembled. The additional temperature switch allows the exhaust system to operate independently of the window position as long as the stove is cold; opening the window is only necessary when the stove is in use. The control unit is simply plugged between the socket and the extractor hood's power plug. The power plug lock prevents the extractor hood's power plug from being accidentally plugged in. The control cables are installed on the window contact switch and the thermal switch. We recommend having this kit installed by a specialist company. The cables must be permanently mounted as surface-mounted cables. Second window The system can be combined with an additional KMS 098K22 cable magnetic switch for a second window. At least one window must then be open for the exhaust system to be activated while the furnace is in operation.

integrated window contact switch from the window manufacturer The KDT 210 includes a cable break protection device (10 kOhm resistor) integrated into the supplied cable magnetic switch. If the KDT 210 is not used with the original cable magnetic switch, but with an integrated switch contact on the window, the following must be observed: To maintain the cable break protection, you must connect the supplied 10 kOhm resistor in parallel with the normally open contact, as shown in the connection example. WEEE NO.: DE91394868
Technical information
Operating voltage 230V AC/50Hz
Switching performance 1150 VA (700 W)/5A (3A)
Functional area -15°C/+40°C
Protection class IP40
TÜV tested TÜV tested
Dimensions(WxWxD)

Control unit 121x57x46 mm, magnet 55x15x18 mm, spacer plate 55x15x5 mm, magnetic switch 55x31x18 mm

Power consumption 18V
Line 6m | 2×0.14mm2 | white
Technical data of related items 201753 ATW 519
Connection examples
FAQ - Frequently asked questions

Technology & function

What does the KDT 210 cable exhaust air control do? The KDT 210 cable exhaust air control ensures safe operation of exhaust systems when a fireplace is being operated in the same room at the same time. The device uses a temperature sensor in the exhaust pipe to detect whether the fireplace (e.g. gas boiler, wood stove) is in operation. As soon as a preset temperature is exceeded, the KDT 210 cable exhaust air control automatically interrupts the power supply to the exhaust system - thus preventing dangerous negative pressure.

How does temperature monitoring work? A thermal switch is located on the fireplace's exhaust pipe. It triggers as soon as the exhaust gas temperature exceeds 40°C (fixed switching point). This information is transmitted via cable to the control unit, which then switches off the exhaust system.

Can I adjust the temperature? No. The trigger temperature is fixed at 40°C - a proven and safe value for detecting the ignition of fireplaces dependent on room air.

Installation

Where is the thermal switch installed? The thermal switch is attached directly to the fireplace's exhaust pipe - ideally with an included pipe clamp or mounting spring. The mounting point should be easily accessible and conduct heat so that the temperature is reliably recorded.

6 meter connection cable is not enough – what can I do? The pre-assembled cables of the KDT 210 set can be extended up to 25 meters using standard two-core cables. However, it should be noted that the KDT 210 is designed as an easy-to-install complete set for easy installation. For larger distances, it is recommended to use the more flexible individual components - such as the KDS 110 control unit in combination with the exhaust gas temperature monitor (item no. 201753).
The temperature sensor is integrated directly into the window contact cable by separating a wire and connecting the sensor in between - a proven solution for longer cable routes or individual planning.

Important note on maintenance: The sensor of the exhaust gas temperature monitor is extremely sensitive to mechanical stress. Please make sure the sensor before cleaning the smoke pipe - especially by a chimney sweep - it is essential to remove it from the pipe. In this way you avoid damage and ensure the long-term functional reliability of the system.

Legal

Does the KDT 210 cable exhaust air control meet the requirements of the combustion regulations? Yes, the device is suitable for use in conjunction with indoor air-dependent fireplaces. It meets the requirements of many state combustion regulations for protection against exhaust gas backflow due to negative pressure. see Fireplace Ordinance (§4 Abs. 2 FeuVo) 

Is the device DIBt approved? No. The KDT 210 cable exhaust air control does not have DIBt approval. If your chimney sweep or the building authority requires approval, you should use an approved model such as the KDS 110 or the KDS 210 set.

purchase & service

Can I install the system myself? The mechanical part (assembly of the thermal switch) can be done yourself with a little technical understanding. However, the electrical installation should always be carried out by a trained electrician.

What happens if the thermal switch breaks? The thermal switch is a proven, purely mechanical component. Should it still fail, the exhaust system remains permanently blocked - a certain malfunction. Replacement is available as an accessory.

Where can I get spare parts or accessories? Accessories such as additional thermal switches or pipe clamps can be obtained directly from Elektrotechnik Schabus or from specialist retailers. Please have the article number or serial number of your device ready.

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)