  • External LNG gas sensor as an accessory for theGas detectors GX-A1 and GX-HS
  • Detection for LNG, town gas, natural gas (methane) and liquefied petroleum gas (propane/butane), R290
  • Leaks from the house installation - gas stove, gas boiler, gas heater, from bottled gases - liquid gases, or leaky fittings
  • Catalytic sensor
  • 2.5 m cable with RJ connector on the cable
  • not in potentially explosive roomsinsert
  • also installed on the SCHABUS socket gas detectors GX-B2pro and GX-B3
  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 300897

Delivery time: 2-3 working days

View full details
Gas sensor GX-LNG

Gas sensor GX-LNG

79,83 €
  • Description
  • Technical information
  • Downloads
  • Reviews

Scope of delivery

  • Gas sensor GX-LNG
  • Instructions for use
  • Mounting material

The GX-LNG gas sensor from Elektrotechnik Schabus is an external sensor specifically designed for the precise detection of flammable gases such as methane, propane, and butane. Combined with the GX-A1+ or GX-HS gas detectors, it offers an effective solution for early warning of gas leaks in a variety of applications.

Versatile gas detection

The GX-LNG sensor is capable of detecting a wide range of gases, including:

  • Natural gas (methane) : Commonly used in households and industrial facilities.

  • Liquefied petroleum gases (propane and butane) : Often found in gas cylinders for heaters, barbecues, or camping equipment.

  • Town gas and LNG (Liquefied Natural Gas) : Used in urban gas supply networks and industrial applications.

  • R290 (propane as refrigerant) : Used in modern cooling systems and heat pumps.

This broad detection capability makes the GX-LNG sensor a versatile instrument for monitoring various gas sources.

Typical areas of application

Thanks to its flexible application possibilities, the GX-LNG sensor is suitable for a wide range of applications:

  • Households : Monitoring of gas stoves, boilers and gas heaters.

  • Motorhomes and caravans : Safety when using gas cylinders for cooking and heating.

  • Commercial kitchens : Protection against gas leaks in catering establishments.

  • Workshops and warehouses : monitoring of gas cylinders and gas-powered equipment.

  • Technical rooms and boiler rooms : Early detection of leaks in gas installations.

Please note that the sensor must not be used in potentially explosive atmospheres .

Commissioning and calibration

During initial operation, the sensor requires a warm-up period of up to 6 days , depending on the ambient conditions. After this period, a self-calibration process is performed to ensure that the sensor achieves the specified measurement accuracy.

The GX-LNG gas sensor provides you with a reliable solution for monitoring and early detection of gas leaks in various environments. We are happy to assist you with further information or specific application questions.

Extension of the connecting cable

The sensor's connecting cable can be extended. The following minimum cross-sections apply depending on the cable length:

Cable cross-section 3 x 0.14 mm²: maximum length 20 m
Cable cross-section 3 x 0.5 mm²: maximum length 50 m

U-sensor output

  • 0% – 1.0 volts
  • 10% – 1.6 volts
  • 20% – 2.3 volts
  • 30% – 2.9 volts

WEEE NO.: DE91394868

Operating voltage 5 V – 24 V DC
Functional area -10°C / +50°C
Protection class IP20
Power consumption 175 mA max-
life approx. 5 years
Line 2.5 m | 2×0.14mm2 | white
sensor catalytic
Control voltage 1-4.5 V output voltage
temperature -20°C / +70°C storage temperature

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description

Scope of delivery

  • Gas sensor GX-LNG
  • Instructions for use
  • Mounting material

The GX-LNG gas sensor from Elektrotechnik Schabus is an external sensor specifically designed for the precise detection of flammable gases such as methane, propane, and butane. Combined with the GX-A1+ or GX-HS gas detectors, it offers an effective solution for early warning of gas leaks in a variety of applications.

Versatile gas detection

The GX-LNG sensor is capable of detecting a wide range of gases, including:

  • Natural gas (methane) : Commonly used in households and industrial facilities.

  • Liquefied petroleum gases (propane and butane) : Often found in gas cylinders for heaters, barbecues, or camping equipment.

  • Town gas and LNG (Liquefied Natural Gas) : Used in urban gas supply networks and industrial applications.

  • R290 (propane as refrigerant) : Used in modern cooling systems and heat pumps.

This broad detection capability makes the GX-LNG sensor a versatile instrument for monitoring various gas sources.

Typical areas of application

Thanks to its flexible application possibilities, the GX-LNG sensor is suitable for a wide range of applications:

  • Households : Monitoring of gas stoves, boilers and gas heaters.

  • Motorhomes and caravans : Safety when using gas cylinders for cooking and heating.

  • Commercial kitchens : Protection against gas leaks in catering establishments.

  • Workshops and warehouses : monitoring of gas cylinders and gas-powered equipment.

  • Technical rooms and boiler rooms : Early detection of leaks in gas installations.

Please note that the sensor must not be used in potentially explosive atmospheres .

Commissioning and calibration

During initial operation, the sensor requires a warm-up period of up to 6 days , depending on the ambient conditions. After this period, a self-calibration process is performed to ensure that the sensor achieves the specified measurement accuracy.

The GX-LNG gas sensor provides you with a reliable solution for monitoring and early detection of gas leaks in various environments. We are happy to assist you with further information or specific application questions.

Extension of the connecting cable

The sensor's connecting cable can be extended. The following minimum cross-sections apply depending on the cable length:

Cable cross-section 3 x 0.14 mm²: maximum length 20 m
Cable cross-section 3 x 0.5 mm²: maximum length 50 m

U-sensor output

  • 0% – 1.0 volts
  • 10% – 1.6 volts
  • 20% – 2.3 volts
  • 30% – 2.9 volts

WEEE NO.: DE91394868

Technical information
Operating voltage 5 V – 24 V DC
Functional area -10°C / +50°C
Protection class IP20
Power consumption 175 mA max-
life approx. 5 years
Line 2.5 m | 2×0.14mm2 | white
sensor catalytic
Control voltage 1-4.5 V output voltage
temperature -20°C / +70°C storage temperature
Connection examples