  • The lifesaver - with the GX-HS you can detect and control LNG, town gas, natural gas and liquefied gases (methane, butane, propane), ethanol, fluorinated refrigerants as well as carbon monoxide (CO), carbon dioxide (CO₂) depending on the connected sensor.
  • interrupts the power supply and optionally the gas line
  • IntegratedLED displayand optionalConnection for external buzzeror piezo alarm
  • Two potential-free relay outputs: for example, for magnetic shut-off valves or integration into building management systems
  • for1 sensorand two additional devices such as warning horn
  • 230 V or 12-24 V DC, 2 potential-free changeover relays, connection to BUS system (EIB)
  • 35 mmDIN rail housing; Sensor placement depending on gas type and room height
  • Carry out maintenance intervals according to the respective sensor
  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 400200

Delivery time: 2-3 working days

View full details
Gas Alarm GX-HS

Gas Alarm GX-HS

108,40 €
  • Description
  • Technical information
  • Downloads
  • Reviews

The Gas Alarm GX-HS is a gas detector for various gases and warns even at gas concentrations far below life-threatening levels. This monitoring system is therefore set to be very sensitive, in keeping with its purpose. A suitable sensor must be used for each gas type. (Information on activation and minimum concentration can be found in the sensor's operating instructions). The alarm signal is emitted visually and audibly by the device (an external buzzer/piezo alarm can be connected to the device as an option). A potential-free relay is also switched, for example to switch a magnetic shut-off valve (locking the gas supply line) with the relay so that no further gas can escape from a potential leak in the gas line or gas boiler. A second relay / fault relay can be used to operate a switching input in the building management system.

Assembly instructions

The warning device and sensor may only be installed in dry indoor areas and must be positioned correctly depending on the gas type to ensure proper functioning of the warning device.

Installation must be carried out by a qualified professional. Please observe the five safety rules!

DIN rail mounting

The Gas Alarm GX-HS is installed in distribution boards and control cabinets on a standard 35 mm DIN rail.

Sensor Installation Depending on the type of sensor connected, the device detects various gases, such as town gas and natural gas (methane/butane), carbon monoxide, smoke, or carbon dioxide. A specified mounting height is required for each sensor type, as gases have different properties and disperse accordingly throughout the room. When using cable extensions, please be sure to refer to the sensor's operating instructions.

Available sensors:

GasInsertSensorItem numberTown & natural gas, methane, butane, propane, LNG, camping gas

gas boiler,

gas stove

GX-LNG 300897 Chlorofluorocarbons
Refrigerants (R-32 and many more)Air conditioning systems
Cold storage facilities
Heat pumps GX-CFC 200901 H2 - Hydrogen air conditioning systems
Heat pumps GX-H2 200616 Carbon dioxide technical systems Dispensing systems
Breweries
Soda maker
Cold rooms
Dry ice storage
technical systems GX-CO2-30 300315 Carbon dioxide indoor air interiors
Workshop
Open-plan office
Waiting room
Event rooms
classroom
Gym GX-CO2-25 20098 9

Overview of connections:

WEEE NO.: DE91394868

Operating voltage 100-240 volts AC / 50-60 Hz, 12 V / 40 V = DC
Switching capacity max. 5 A / 230 V relay
Functional area -10°C / +60°C
Protection class IP20
Power consumption approx. 1 W (standby)
alarm 9 – 15 V / 30 mA, acoustic, optical
Relay contact 2 potential-free changeover contacts, changeover contact NC / NO
Assembly DIN rail device
Sensor connection 1×24 VDC / max. 150 mA, 1×5 VDC / max. 200 mA

Operating instructions

 

CE declaration / EU declaration of conformity

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description

The Gas Alarm GX-HS is a gas detector for various gases and warns even at gas concentrations far below life-threatening levels. This monitoring system is therefore set to be very sensitive, in keeping with its purpose. A suitable sensor must be used for each gas type. (Information on activation and minimum concentration can be found in the sensor's operating instructions). The alarm signal is emitted visually and audibly by the device (an external buzzer/piezo alarm can be connected to the device as an option). A potential-free relay is also switched, for example to switch a magnetic shut-off valve (locking the gas supply line) with the relay so that no further gas can escape from a potential leak in the gas line or gas boiler. A second relay / fault relay can be used to operate a switching input in the building management system.

Assembly instructions

The warning device and sensor may only be installed in dry indoor areas and must be positioned correctly depending on the gas type to ensure proper functioning of the warning device.

Installation must be carried out by a qualified professional. Please observe the five safety rules!

DIN rail mounting

The Gas Alarm GX-HS is installed in distribution boards and control cabinets on a standard 35 mm DIN rail.

Sensor Installation Depending on the type of sensor connected, the device detects various gases, such as town gas and natural gas (methane/butane), carbon monoxide, smoke, or carbon dioxide. A specified mounting height is required for each sensor type, as gases have different properties and disperse accordingly throughout the room. When using cable extensions, please be sure to refer to the sensor's operating instructions.

Available sensors:

GasInsertSensorItem numberTown & natural gas, methane, butane, propane, LNG, camping gas

gas boiler,

gas stove

GX-LNG 300897 Chlorofluorocarbons
Refrigerants (R-32 and many more)Air conditioning systems
Cold storage facilities
Heat pumps GX-CFC 200901 H2 - Hydrogen air conditioning systems
Heat pumps GX-H2 200616 Carbon dioxide technical systems Dispensing systems
Breweries
Soda maker
Cold rooms
Dry ice storage
technical systems GX-CO2-30 300315 Carbon dioxide indoor air interiors
Workshop
Open-plan office
Waiting room
Event rooms
classroom
Gym GX-CO2-25 20098 9

Overview of connections:

WEEE NO.: DE91394868

Technical information
Operating voltage 100-240 volts AC / 50-60 Hz, 12 V / 40 V = DC
Switching capacity max. 5 A / 230 V relay
Functional area -10°C / +60°C
Protection class IP20
Power consumption approx. 1 W (standby)
alarm 9 – 15 V / 30 mA, acoustic, optical
Relay contact 2 potential-free changeover contacts, changeover contact NC / NO
Assembly DIN rail device
Sensor connection 1×24 VDC / max. 150 mA, 1×5 VDC / max. 200 mA