  • CO2 warning device for tea kitchens
  • Alarm thresholds according to DIN EN 6653-2 | 3.0% vol. CO2
  • Simple, quick installation, 3 minutes preheating time
  • acoustic and visual warning
  • Detection of carbon dioxide (CO2) from technical systems
  • Monitoring of cold rooms, beverage dispensing systems, tea kitchens with water dispensers

Include your professional association and the trade supervisory authority in your planning prior to installation to ensure that nothing stands in the way of subsequent acceptance. There are significant regional differences over which Elektrotechnik Schabus has no influence.

  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 300257

Delivery time: 2-3 working days

View full details
GAS ALARM GX-D33

GAS ALARM GX-D33

150,84 €
  • Description
  • Technical information
  • Downloads
  • Reviews
The CO2 alarm GX-D33 is a CO2 warning device for technical CO2 systems with pressure cylinders and poorly ventilated dry ice storage facilities.
The GX-D33 is ideal for the so-called tea kitchens in offices where large CO2 bottles for water carbonators are set up.
The alarm thresholds were set high enough to detect technical defects immediately, but not to immediately raise the alarm in the case of poor indoor air contaminated with CO2 from exhaled carbon dioxide.
The GX-D33 is simply plugged into a free socket in the lower area, which is located near the CO2 cylinders to be monitored, and is ready for use after 3 minutes.
Its internal infrared sensor operates maintenance-free for years as long as it never comes into contact with water.
For your safety, we recommend that you carry out a functional test with your breath every six months. The exact description can be found in the operating instructions.

It is advisable to consult the relevant trade inspectorate or trade association before installing and commissioning CO₂ warning devices to ensure that all regional and specific safety regulations are observed.

https://youtu.be/aDaF36zQ2BA?si=eL8MDzNtn2v5npbO WEEE NO.: DE91394868
Operating voltage 230V ~ (+/-10%)V AC / 50-60Hz
Functional area 0°C / +40°C
Protection class IP20
Power consumption max. 3 VA
humidity 5-90% rH
Trigger concentration 1.5% pre-alarm, 3.0% main alarm, according to DIN EN 6653-2
Sound pressure level 90 dB (10 cm distance)
sensor internal, NDIR infrared
temperature -20°C / +70°C storage temperature

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description
The CO2 alarm GX-D33 is a CO2 warning device for technical CO2 systems with pressure cylinders and poorly ventilated dry ice storage facilities.
The GX-D33 is ideal for the so-called tea kitchens in offices where large CO2 bottles for water carbonators are set up.
The alarm thresholds were set high enough to detect technical defects immediately, but not to immediately raise the alarm in the case of poor indoor air contaminated with CO2 from exhaled carbon dioxide.
The GX-D33 is simply plugged into a free socket in the lower area, which is located near the CO2 cylinders to be monitored, and is ready for use after 3 minutes.
Its internal infrared sensor operates maintenance-free for years as long as it never comes into contact with water.
For your safety, we recommend that you carry out a functional test with your breath every six months. The exact description can be found in the operating instructions.

It is advisable to consult the relevant trade inspectorate or trade association before installing and commissioning CO₂ warning devices to ensure that all regional and specific safety regulations are observed.

https://youtu.be/aDaF36zQ2BA?si=eL8MDzNtn2v5npbO WEEE NO.: DE91394868
Technical information
Operating voltage 230V ~ (+/-10%)V AC / 50-60Hz
Functional area 0°C / +40°C
Protection class IP20
Power consumption max. 3 VA
humidity 5-90% rH
Trigger concentration 1.5% pre-alarm, 3.0% main alarm, according to DIN EN 6653-2
Sound pressure level 90 dB (10 cm distance)
sensor internal, NDIR infrared
temperature -20°C / +70°C storage temperature