• Differential pressure controller DS01 L
  • Differential pressure controller DS01 L
  • Differential pressure controller DS01 L
  • Differential pressure controller DS01 L

Differential pressure controller DS01 L

Differential pressure controller DS01 L

Regular price 1.000,00 €
Regular price Sale price 1.000,00 €
Sale Sold out
Taxes included. Versandkosten

Differential pressure controller DS 01

  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 21000

Delivery time: 2-3 working days

View full details
Differential pressure controller DS01 L

Differential pressure controller DS01 L

1.000,00 €
  • Description
  • Technical information
  • Downloads
  • Reviews

Scope of delivery

  • Control unit DS01
  • detailed operating and assembly instructions

Be sure to order any necessary accessories !

The DS01 L differential pressure controller is a safety device that enables the simultaneous operation of room-air-dependent solid fuel fireplaces with ventilation systems (not suitable for open fireplaces or open operation). The negative pressure in the chimney connection compared to the surrounding room (= installation room or air connection) is continuously monitored during stove operation. This prevents negative pressure from developing in the installation room/air connection, preventing dangerous amounts of flue gas from escaping through the fireplace into the installation room. The integrated evaluation logic prevents overly sensitive response to wind pressure fluctuations or during a cold start of the fireplace. A plausibility check is also performed. If the air pressure monitor switches off the connected system, sufficient fresh air must be provided to restart it. Note: The DIBt approval applies exclusively to controlled residential ventilation systems, not to extractor hoods, although the DS01L also functions with these.

Talk to your chimney sweep and include him in your planning so that nothing stands in the way of a later inspection.
Automatic reset – automatic restart of the ventilation system after a fault.
The pressure measuring adapter (1) and temperature measuring adapter (2) provide the necessary data for operating this electronic safety device in buildings with controlled domestic ventilation. The adapter rosette (3), available in black or silver-gray, ensures an attractive appearance by simply sliding it over the flue pipe. The rosette is available to fit flue pipes with a diameter of 130 or 150 mm.

useful additions

WEEE NO.: DE91394868

Operating voltage 230 V AC / 50 Hz
Switching capacity max. 2 A | 250 V~ or 50 V ≈
Functional area 0 °C / +60 °C
Protection class IP54
TÜV tested TÜV-tested
DIBt certificate DIBt Z-85.1-2
Power consumption max. 3 VA
brand Wodtke
Pressure -50 to 200 Pa | up to 1 kPa overload
Nominal measuring range -50 to +50 Pa

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description

Scope of delivery

  • Control unit DS01
  • detailed operating and assembly instructions

Be sure to order any necessary accessories !

The DS01 L differential pressure controller is a safety device that enables the simultaneous operation of room-air-dependent solid fuel fireplaces with ventilation systems (not suitable for open fireplaces or open operation). The negative pressure in the chimney connection compared to the surrounding room (= installation room or air connection) is continuously monitored during stove operation. This prevents negative pressure from developing in the installation room/air connection, preventing dangerous amounts of flue gas from escaping through the fireplace into the installation room. The integrated evaluation logic prevents overly sensitive response to wind pressure fluctuations or during a cold start of the fireplace. A plausibility check is also performed. If the air pressure monitor switches off the connected system, sufficient fresh air must be provided to restart it. Note: The DIBt approval applies exclusively to controlled residential ventilation systems, not to extractor hoods, although the DS01L also functions with these.

Talk to your chimney sweep and include him in your planning so that nothing stands in the way of a later inspection.
Automatic reset – automatic restart of the ventilation system after a fault.
The pressure measuring adapter (1) and temperature measuring adapter (2) provide the necessary data for operating this electronic safety device in buildings with controlled domestic ventilation. The adapter rosette (3), available in black or silver-gray, ensures an attractive appearance by simply sliding it over the flue pipe. The rosette is available to fit flue pipes with a diameter of 130 or 150 mm.

useful additions

WEEE NO.: DE91394868

Technical information
Operating voltage 230 V AC / 50 Hz
Switching capacity max. 2 A | 250 V~ or 50 V ≈
Functional area 0 °C / +60 °C
Protection class IP54
TÜV tested TÜV-tested
DIBt certificate DIBt Z-85.1-2
Power consumption max. 3 VA
brand Wodtke
Pressure -50 to 200 Pa | up to 1 kPa overload
Nominal measuring range -50 to +50 Pa