• CO2 Ampel Faktory Produktbild
  • CO2 Ampel Factory Anwendung Comic Clip
  • CO2 Ampel Faktory Produktbild
  • CO2 traffic light "Factory"
  • CO2 Ampel Factory Anwendung Comic Clip
  • CO2 traffic light "Factory"
  • CO2 traffic light "Factory"

CO2 traffic light "Factory"

CO2 traffic light "Factory"

Normal price 299,00 €
Normal price Selling price 299,00 €
Sale Sold out
including VAT plus Versandkosten
  • Messung von Kohlendioxid (CO2) in der Raumluft mittels internem Infrarot-Sensor (NDR)
  • gelbe LED < 1400 ppm gelb
  • rote LED < 2000 ppm rot
  • rote LED blinkend < 2500 ppm zusätzlich akustische Warnung
  • Energiesparend durch zielgerichtetes Lüften, LED mit automatischer Nachtabdunkelung
  • Raumluftüberwachung im Büro nach EU Norm EN 13779
  • Einzelbüro, Empfangsbüros, Großraumbüro, Meeting-Räume, Produktionsstätten, Werkstätten uvm.
  • zuverlässige Erinnerung zum regelmäßigen Stoßlüften
  • einfache Installation mit Wandhalterung und Netzstecker
  • Standard Farbe Weiß (RAL 9016), optional Grau (RAL 7032) oder Grün (RAL 6024), auf Wunsch alle RAL Farben möglich
  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

Item number: 400360

Delivery time: 2-3 working days

View full details
CO2 Ampel Faktory Produktbild

CO2 traffic light "Factory"

299,00 €
  • Description
  • Technical information
  • Downloads
  • Reviews
Scope of delivery
  • CO2 traffic light with 0.8 m cable and wall mounting set
  • 12 V plug-in power supply with 1.5 m cable
  • Operating instructions
The optical warning device detects elevated CO2 levels in indoor spaces where large numbers of people regularly gather. Typically, these are production facilities, workshops, open-plan offices, and generally all indoor spaces. 1400 ppm of CO2 in the indoor air is already considered "very poor air." The maximum workplace concentration (MAK) in Germany is 5000 ppm. Therefore, the "factory" CO2 traffic light, with its yellow light starting at 1400 ppm, reminds people to thoroughly ventilate the room. Those who constantly breathe poor, stale air become tired and significantly lose their ability to perform and concentrate. This has a particularly negative impact on learning and working. The immune system is also weakened, or noticeably strengthened and stabilized with constant fresh air, which can be seen, for example, in open-plan offices, even on sick days throughout the year. The only remedy for poor air quality is regular ventilation, which is often and easily forgotten. This is precisely where the CO2 traffic light comes in. Not only does it warn of significantly increased harmful concentrations, but it also encourages you to ventilate in good time, even before the warning signal sounds at the highest warning level.
Important information about all CO2 traffic lights
Please do not unplug your traffic light overnight! The traffic light uses the nighttime quiet periods to calibrate itself correctly – just like with regular, daily ventilation in the rooms. Therefore, please leave the traffic light permanently switched on, i.e. connected to the mains, during business and/or school hours. The traffic light remembers the lowest CO2 concentration of the last 7 days and resets itself to its theoretical zero point at this rate. For this automatic calibration, the weekly average is significantly more meaningful than a daily average. To save energy, the traffic light has a light sensor that dims the LEDs after 10 minutes of total darkness, thus reducing the overall power consumption.
That’s why it’s so important to supply the traffic lights with power at night too.
The traffic light can only be taken off the grid during company holidays of more than 7 days.
 
WEEE NO.: DE91394868
Operating voltage 12 V DC from plug-in power supply
Functional area +5°C/+45°C
Protection class IP20
Dimensions(WxWxD)

303x55x80mm

Color Protection class
Line approx. 150 cm power supply cable, approx. 80 cm traffic light cable
Humidity 10% – 90% rH, non-condensing
Trigger concentration 2500 ppm CO2, 2000 ppm CO2, 1400 ppm CO2
Sensor internal, NDIR infrared

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description
Scope of delivery
  • CO2 traffic light with 0.8 m cable and wall mounting set
  • 12 V plug-in power supply with 1.5 m cable
  • Operating instructions
The optical warning device detects elevated CO2 levels in indoor spaces where large numbers of people regularly gather. Typically, these are production facilities, workshops, open-plan offices, and generally all indoor spaces. 1400 ppm of CO2 in the indoor air is already considered "very poor air." The maximum workplace concentration (MAK) in Germany is 5000 ppm. Therefore, the "factory" CO2 traffic light, with its yellow light starting at 1400 ppm, reminds people to thoroughly ventilate the room. Those who constantly breathe poor, stale air become tired and significantly lose their ability to perform and concentrate. This has a particularly negative impact on learning and working. The immune system is also weakened, or noticeably strengthened and stabilized with constant fresh air, which can be seen, for example, in open-plan offices, even on sick days throughout the year. The only remedy for poor air quality is regular ventilation, which is often and easily forgotten. This is precisely where the CO2 traffic light comes in. Not only does it warn of significantly increased harmful concentrations, but it also encourages you to ventilate in good time, even before the warning signal sounds at the highest warning level.
Important information about all CO2 traffic lights
Please do not unplug your traffic light overnight! The traffic light uses the nighttime quiet periods to calibrate itself correctly – just like with regular, daily ventilation in the rooms. Therefore, please leave the traffic light permanently switched on, i.e. connected to the mains, during business and/or school hours. The traffic light remembers the lowest CO2 concentration of the last 7 days and resets itself to its theoretical zero point at this rate. For this automatic calibration, the weekly average is significantly more meaningful than a daily average. To save energy, the traffic light has a light sensor that dims the LEDs after 10 minutes of total darkness, thus reducing the overall power consumption.
That’s why it’s so important to supply the traffic lights with power at night too.
The traffic light can only be taken off the grid during company holidays of more than 7 days.
 
WEEE NO.: DE91394868
Technical information
Operating voltage 12 V DC from plug-in power supply
Functional area +5°C/+45°C
Protection class IP20
Dimensions(WxWxD)

303x55x80mm

Color Protection class
Line approx. 150 cm power supply cable, approx. 80 cm traffic light cable
Humidity 10% – 90% rH, non-condensing
Trigger concentration 2500 ppm CO2, 2000 ppm CO2, 1400 ppm CO2
Sensor internal, NDIR infrared
Connection examples
FAQ - Frequently asked questions
Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)