• CO detector according to DIN EN 50291
  • CO detector according to DIN EN 50291
  • CO detector according to DIN EN 50291
  • CO detector according to DIN EN 50291

CO detector according to DIN EN 50291

CO detector according to DIN EN 50291

Regular price 226,05 €
Regular price Sale price 226,05 €
Sale Sold out
Taxes included. Versandkosten
  • Monitoring device for safety shutdown of the boiler in case of carbon monoxide leakage
  • Detection of carbon monoxide (CO) afterDIN EN 50291 TÜV-tested
  • Alarm threshold:50 ppm COaccording to DIN EN 50 291-1
  • for gas boilers, gas heating, gas stove, gas oven, oil heating and any combustion facility with supply
  • CO sensor lifespan: approx. 6 years at max. 40°C | min. 40% rH, approx. 10 years at max. 28°C | 30% rH
  • double security throughacoustic and visual warning functionandautomatic shutdownof the connected device in case of gas leakage
  • regular automatic self-test function
  • intelligent self-test, long-lasting electrochemical sensor, test button and much more.

 

Be sure to check the type plate on the back to find the right sensor for you!

The alternative sensor can be found under article number: 7639852

  • Discounts for specialist companies & resellers
  • Personal expert advice (no call center!)
  • Repair service beyond the statutory warranty

SKU: 7549937

Delivery time: 2-3 working days

View full details
CO detector according to DIN EN 50291

CO detector according to DIN EN 50291

226,05 €
  • Description
  • Technical information
  • Downloads
  • Reviews

Scope of delivery

  • CO detector
  • 2 keyholes on the back wall, 2 screws/dowels included

Reliable protection against carbon monoxide

The CO detector, which complies with DIN EN 50291, was specifically designed to protect people from the acute dangers of carbon monoxide (CO). At a CO concentration of 50 ppm, the connected boiler automatically shuts down, immediately deactivating potential sources of danger. Thanks to its TÜV-tested technology and compliance with DIN EN 50291, this device offers the highest level of safety for your home.

  • Monitoring device for the safety shutdown of the boiler in the event of carbon monoxide leakage. Alarm threshold: 50 ppm CO according to DIN EN 50 291-1
  • This device was developed to protect people from the immediate effects of carbon monoxide exposure. CO sensor lifespan: approx. 6 years (max. 40°C, min. 40% rH), approx. 10 years (max. 28°C, 30% rH)

Important instructions

Certain substances such as ethylene, ethanol, alcohol, isopropanol, gasoline, toluene, ethyl acetate, hydrogen, hydrogen sulfide, and sulfur dioxide can interfere with the CO detector and potentially trigger false alarms. Avoid using the device in rooms where these substances are present.

People with specific medical conditions should be aware that this CO detector may not provide adequate protection. In such cases, it is recommended to use a warning device that generates audible and/or visible signals at CO concentrations below 50 ppm. If in doubt, consult a physician.

For further information or personal advice, the team at Elektrotechnik Schabus will be happy to assist you

WEEE NO.: DE91394868

Operating voltage 24 volts DC (+/- 10%)
Functional area 0°C / +40°C
Protection class according to DIN EN 60529, IP 20
Dimensions (W x W x D) Sensor 88x58x38xmm
Power consumption 29-31 mA monitoring mode, 38-41 mA alarm mode, max. 46 mA test mode
Connection 6-pin, 3 of which are occupied, mechanical, RJ12 socket
Output signal 20 Hz nominal (19.8-20.8 Hertz), Hi 23-27 ms (error), Hi 3-7 ms (operation), Lo 8-12 ms (alarm)
Evaluation OP-AD-DA, quasi-linear after calibration +/- 1 %
Weight 0.10 kg
life 6 – max. 10 years (depending on environmental conditions)
humidity 10% – 90% rH, non-condensing
Sound pressure level 4.4 kHz, 85 dB(A) @ 1 m

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Description

Scope of delivery

  • CO detector
  • 2 keyholes on the back wall, 2 screws/dowels included

Reliable protection against carbon monoxide

The CO detector, which complies with DIN EN 50291, was specifically designed to protect people from the acute dangers of carbon monoxide (CO). At a CO concentration of 50 ppm, the connected boiler automatically shuts down, immediately deactivating potential sources of danger. Thanks to its TÜV-tested technology and compliance with DIN EN 50291, this device offers the highest level of safety for your home.

  • Monitoring device for the safety shutdown of the boiler in the event of carbon monoxide leakage. Alarm threshold: 50 ppm CO according to DIN EN 50 291-1
  • This device was developed to protect people from the immediate effects of carbon monoxide exposure. CO sensor lifespan: approx. 6 years (max. 40°C, min. 40% rH), approx. 10 years (max. 28°C, 30% rH)

Important instructions

Certain substances such as ethylene, ethanol, alcohol, isopropanol, gasoline, toluene, ethyl acetate, hydrogen, hydrogen sulfide, and sulfur dioxide can interfere with the CO detector and potentially trigger false alarms. Avoid using the device in rooms where these substances are present.

People with specific medical conditions should be aware that this CO detector may not provide adequate protection. In such cases, it is recommended to use a warning device that generates audible and/or visible signals at CO concentrations below 50 ppm. If in doubt, consult a physician.

For further information or personal advice, the team at Elektrotechnik Schabus will be happy to assist you

WEEE NO.: DE91394868

Technical information
Operating voltage 24 volts DC (+/- 10%)
Functional area 0°C / +40°C
Protection class according to DIN EN 60529, IP 20
Dimensions (W x W x D) Sensor 88x58x38xmm
Power consumption 29-31 mA monitoring mode, 38-41 mA alarm mode, max. 46 mA test mode
Connection 6-pin, 3 of which are occupied, mechanical, RJ12 socket
Output signal 20 Hz nominal (19.8-20.8 Hertz), Hi 23-27 ms (error), Hi 3-7 ms (operation), Lo 8-12 ms (alarm)
Evaluation OP-AD-DA, quasi-linear after calibration +/- 1 %
Weight 0.10 kg
life 6 – max. 10 years (depending on environmental conditions)
humidity 10% – 90% rH, non-condensing
Sound pressure level 4.4 kHz, 85 dB(A) @ 1 m