{"title":"Gas boiler control","description":"","products":[{"product_id":"kabel-abluftsteuerung-kgs-116","title":"Cable exhaust air control KGS 116","description":"\u003cp\u003e \u003cstrong\u003eScope of delivery\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e control unit\u003c\/li\u003e\n\n\u003cli\u003e 4 m control cable\u003c\/li\u003e\n\n\u003cli\u003e Mounting material\u003c\/li\u003e\n\n\u003cli\u003e Operating instructions\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n \u003cp\u003eExhaust systems such as bathroom fans or extractor hoods create negative pressure in the room if there is insufficient fresh air flow. If a fireplace (e.g., gas boiler, central heating boiler) is located in the same room, there is a risk that toxic exhaust gases – such as carbon monoxide – will be sucked back into the living space from the chimney.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp data-start=\"486\" data-end=\"645\"\u003e The \u003cstrong data-start=\"490\" data-end=\"517\"\u003eKGS 116 exhaust air control system\u003c\/strong\u003e prevents precisely this risk: It only allows the exhaust air system to operate when the fireplace is \u003cem data-start=\"622\" data-end=\"629\"\u003enot\u003c\/em\u003e in use.\u003c\/p\u003e\n\n\u003cp data-start=\"647\" data-end=\"901\"\u003e The control unit is permanently connected to the potential-free contact of the gas boiler (normally open). As soon as the boiler ignites, the KGS 116 detects the changed contact state and interrupts the power supply to the connected exhaust air system.\u003c\/p\u003e\n\n\u003cp data-start=\"903\" data-end=\"1002\"\u003e If the gas boiler is deactivated again, the control system automatically releases the exhaust air system again.\u003c\/p\u003e\n\n \u003cp data-start=\"1004\" data-end=\"1088\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1027\"\u003eSafety principle:\u003c\/strong\u003e Exhaust air is only permitted if no exhaust gases can be produced.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch3\u003e Connection example\u003c\/h3\u003e\n\n\u003cp\u003e The KGS 116 cable gas boiler control system queries the potential-free normally open contact of a gas boiler and converts the gas boiler's state change into a switching of the potential-free changeover relay. This system can be used to turn off a bathroom fan, for example, when the gas boiler is ignited. \u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0915\/2587\/4039\/files\/300715_ABSP_01_2021-11-29_SCHABUS_8d864fab-8c3c-4144-a3c2-8e7a23d018dd.webp?v=1754956526\" alt=\"\"\u003e\u003c\/p\u003e\n\n\u003cp\u003e The KGS 116 control unit is connected to the potential-free contact (normally open) of the gas boiler with a cable. As soon as combustion starts, the exhaust air system (e.g., bathroom fan) is switched off. The control unit can be installed surface-mounted or flush-mounted in a distribution box, switch, or socket with a minimum diameter of 60 mm. The side mounting tabs on the control unit can be removed if necessary.\u003c\/p\u003e\n\n\u003cp\u003e WEEE NO.: DE91394868\u003c\/p\u003e","brand":"Elektrotechnik-Schabus","offers":[{"title":"Default Title","offer_id":55582120214903,"sku":"300715","price":79.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/2587\/4039\/files\/300715-KGS116-SCHABUS-4-1.webp?v=1759960119"},{"product_id":"funk-abluftsteuerung-fgs-171","title":"Wireless exhaust air control FGS 170","description":"\u003cdiv\u003e\n\n \u003cstrong\u003eScope of delivery\u003c\/strong\u003e\u003cbr\u003e • Radio receiver\u003cbr\u003e • Radio transmitter\u003cbr\u003e • 4 m control cable\u003cbr\u003e • Operating instructions, mounting material (10 nail clamps, screwdriver)\u003c\/div\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cdiv\u003e\n\n\u003cp data-start=\"460\" data-end=\"784\"\u003e Exhaust systems such as bathroom fans or extractor hoods create negative pressure in the room if there is insufficient fresh air flow. If a fireplace (e.g., gas boiler, central heating boiler) is located in the same room, there is a risk that toxic exhaust gases – such as carbon monoxide – will be sucked back into the living space from the chimney.\u003c\/p\u003e\n\n \u003cp data-start=\"786\" data-end=\"952\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"790\" data-end=\"822\"\u003eWireless exhaust air control FGS 170\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents exactly this risk: It allows the operation of the exhaust air system only when the fireplace\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"927\" data-end=\"936\"\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis in operation.\u003c\/p\u003e\n\n\u003cp data-start=\"981\" data-end=\"1327\"\u003e The control system consists of a transmitter and a receiver. The transmitter is connected to the potential-free output of the gas boiler (normally closed or normally closed). As soon as the boiler ignites, the contact state changes – the signal is transmitted wirelessly to the receiver. The receiver then shuts off the power supply to the exhaust air system.\u003c\/p\u003e\n\n\u003cp data-start=\"1329\" data-end=\"1406\"\u003e If the boiler is deactivated again, the receiver releases the exhaust air system.\u003c\/p\u003e\n\n\u003cp data-start=\"1329\" data-end=\"1406\"\u003e \u003cstrong data-start=\"1413\" data-end=\"1435\"\u003eSafety principle\u003c\/strong\u003e : Exhaust air is only permitted if no exhaust gases can be produced.\u003c\/p\u003e\n\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv\u003e \u003cb\u003eSecond recipient\u003c\/b\u003e\n\u003c\/div\u003e\n\n \u003cdiv\u003eAn additional receiver can be added to the existing FGS 170 set\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.elektrotechnik-schabus.de\/abluftsteuerungen\/funksysteme\/funk-empfanger-fgs-170-e\" data-mil=\"80\"\u003e\u003cb\u003eFGS 170-E\u003c\/b\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ethe same factory coding (0 to 9). When ordering, please specify the serial number of your existing set.\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e WEEE NO.: DE91394868\u003c\/p\u003e","brand":"Elektrotechnik-Schabus","offers":[{"title":"Default Title","offer_id":55587162292599,"sku":"300714","price":173.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/2587\/4039\/files\/300714-1-Hero-FGS170-Funk-Gasthermensteuerung-fuer-Badluefter_1.jpg?v=1785492030"},{"product_id":"funk-empfanger-fgs-170-e","title":"Radio receiver FGS 170-E","description":"\u003cp\u003eExhaust systems such as bathroom fans create negative pressure in the room if there isn't enough air flow. If a combustion unit (e.g., a gas boiler) is located in the same room, dangerous exhaust gases can escape and spread throughout the room.\u003cbr\u003e By using the FGS 170 wireless exhaust air control, an exhaust air system can only be used when, for example, this gas boiler is not ignited.\u003cbr\u003e The gas boiler must have a potential-free contact (normally closed or normally closed) that is queried by the FGS 170 and transmits the operating status of the gas boiler to the receiver.\u003cbr\u003e You can get the additional receiver FGS 170-E (article 300701, page 27) for additional fans (specifying the serial number of the existing set) only in our online shop and not in stores, as we produce additional devices especially for you.\u003c\/p\u003e\n\n\u003cp\u003e \u0026amp;nbsp;\u003c\/p\u003e\n\n\u003cp\u003e \u0026lt;strong\u0026gt;My gas boiler only produces 230 volts when ignited.\u0026lt;\/strong\u0026gt; \u003cbr\u003eThis happens quite often, but it's better than no message at all. Ask your electrician to bring a 230V relay with them for installation, so they can create a potential-free contact and thus control the FGS 170 transmitter.\u003c\/p\u003e\n\n\u003cp\u003e \u0026amp;nbsp;\u003c\/p\u003e\n\n\u003cp\u003e \u0026amp;nbsp;\u003c\/p\u003e\n\n\u003cp\u003e \u0026lt;img class=\"alignleft wp-image-15519 size-full\" src=\"https:\/\/www.elektrotechnik-schabus.de\/wp-content\/uploads\/300714_ABSP_01_BORA_2021-11-11_SCHABUS.jpg\" alt=\"\" width=\"2235\" height=\"634\" \/\u0026gt;\u003c\/p\u003e\n\n \u003cp\u003eThe transmitter is connected to the potential-free contact (normally closed) of the gas boiler with a cable. As soon as combustion starts and the contact opens, a receiver is wirelessly controlled, which switches off the exhaust system (e.g., bathroom fan). The receiver can be installed surface-mounted or flush-mounted in a distribution box, switch, or socket with a diameter of at least 60 mm. The side mounting tabs on the receiver can be removed if necessary. *Ensure that the radio waves are not shielded (by walls, metal, etc.); the range depends on the installation.\u003c\/p\u003e\n\n\u003cp\u003e \u0026amp;nbsp;\u003c\/p\u003e\n\n\u003cp\u003e WEEE NO.: DE91394868\u003c\/p\u003e","brand":"Elektrotechnik-Schabus","offers":[{"title":"Default Title","offer_id":55591830749559,"sku":"300701","price":85.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0915\/2587\/4039\/files\/300701_FGS170-E_Zusatzempf_nger-300x300.jpg?v=1762863909"}],"url":"https:\/\/www.elektrotechnik-schabus.de\/en\/collections\/gasthermensteuerung-1.oembed","provider":"Elektrotechnik-Schabus","version":"1.0","type":"link"}